AP Diving Ltd. RBV07 Swivel Inflator Range Maintenance Manual
Page 46 of 50
7.11 When a GC3 Flowstop is fitted: fit new O-rings to both ends of MP
hose
- Fit new O-rings to both hose ends.
-
ATTENTION
: make sure to fit the hose the correct way around. Notice that the ends are
different:
o
The end with the protruding connection goes onto the solenoid; the end with
the recessed connection goes onto the GC3 Flowstop.
o
If the hose is fitted the wrong way around, you will not be able to screw the
hose end all the way down onto the GC3 Flowstop, showing exposed threads
(see picture below on the left).
o
In that case neither end of the hose will be properly secured.
Incorrect
Correct
The connection on the left is incorrect, as a result of the hose being
connected the wrong way around. Notice the exposed threads.
GC3 Flowstop end
Solenoid end