AP Diving Ltd. RBV07 Swivel Inflator Range Maintenance Manual
Page 15 of 50
4.2 Tools Needed
There are no special tools needed for servicing the RBV07 Swivel inflator.
Normal tools needed are:
- A 5mm Allen key
- 8, 12,13, 14 and 24mm spanners
- A torque wrench for low torque settings (down to 4 Newton Meter)
- A screw driver
- a bench vice, fitted with soft jaws
- O-ring picking tools
- Oxygen-compatible grease
o
see chapter 5 for remarks about when you need to keep this device in oxygen
service
- (Access to) an ultrasonic bath for cleaning the metal parts.
WARNING:
Do NOT use aggressive chemicals. They might damage the metal plating of
the RBV07 Swivel inflator. Use an ultrasonic cleaning bath with a suitable cleaning fluid. A
very good cleaning fluid is Biox “O2” immersion fluid. See WWW.BIOXINT.COM for further
information and distributors.
The use of rubber gloves while re-assembling the RBV07 Swivel inflator is recommended to
avoid rendering the RBV07 Swivel inflator oxygen unclean due to human touch.