AP Diving Ltd. RBV07 Swivel Inflator Range Maintenance Manual
Page 43 of 50
7.7 Screw the GC3 Flowstop isolator back into the 5/16”-9/16” adapter
-
ATTENTION
: This step only applies to the RBV07(A)/SO and RBV07(A)/DUAL/SO
versions of the inflator, which are fitted with a GC3 in-line gas isolator.
- Use a 14 mm spanner to screw the GC3 Flowstop back into its associated adapter.
7.8 Screw the 5/16” inflator stem(s) back into the inflator body
- Fit new O-rings onto the base of the inflator stem(s).
- Use an 8 mm spanner to screw the inflator stem back into the inflator body.