15
9. Enter soldering iron function and set to desire temperature, check
if additional calibration is needed. If additional calibration is
needed repeat steps 1 to 8 and each time adjusting the
calibration value slightly higher or lower based on the previously
entered values.
M. Utilizing the Hot Air Gun Digital Temperature Calibration
By default, the system is properly calibrated but for some
cases when a little adjustment of the Hot Air Gun temperature is
required the following procedure can be done.
1. Follow System Setting procedures 1 to 6. Adjust system
selection menu to “ 3”, then press the hot air gun increase
temperature adjustment button “B3”.
2. If successful the display would show “ 000” indicating hot air gun
digital calibration is being set.
3. A lighted Soldering Iron heater indicator LED ”A1” indicates that
the number shown is a positive calibration value, an unlit
Soldering Iron heater indicator LED “A1” indicates that the
number shown is a negative calibration value.
4. Adjust the air flow adjustment knob “B3” to enter desired offset
value, Calibration value can be adjusted from –70 to 70 degrees
with “ 000” signifying no offset.
5. Save the selected calibration settings and exit from the
calibration adjustment menu by pressing the soldering iron
function switch “A4”.
6. Enter hot air gun function and set to desire temperature to check
if additional calibration is needed.