8
CONTROL PANEL GUIDE
LEGEND:
1 — Air Gauge
2 — Hot Air Gun Temperature Control Buttons
3 — Air Pressure Control Buttons
4 — Auto Rework Time Adjustment Buttons
5 — Soldering Iron Temperature Control Buttons
6 — Hot Air Output Terminal
7 — Smoke absorber connector
8 — Soldering Iron 5Pin Connecting Terminal
9 — Main power switch
10 — Function selector
11 — Hot Air Gun Temperature Display
12 — Hot Air Gun Pressure Display
13 — Auto Rework Time Display
14 — Soldering Iron Temperature Display
15 — Hot Air Gun Activation Switch
16 — Auto Reworking Activation Switch
17 — Reset
18 — Soldering Iron Activation Switch
19 — Vacuum indicator
738
Power
Vacuum
Smoke
absorber
SMD
REWORK
15
16
17
18
19
17
STEPS in Checking, Cleaning and Tinning the Tip
1.
Set temperature to 250
°
C (482
°
F)
2.
After real temperature reaches the set temperature, use a damp
sponge to clean the tip and check for damages.
3.
If the tip has oxidation, apply solder and wipe using the damp
sponge, repeat these steps until oxidation is removed.
4.
After cleaning, coat tip with a thin layer of solder and set it aside
ready for the next usage.
5.
If the tip shows disfiguration or has rust on it. Change the tip.
The hand piece may be disassembled for trouble shooting and
repair:
1.
Turn of main station and unplug from power source.
2.
Detach the soldering iron plug(”15” as shown in the figure below)
from the main unit.
3.
Turn the nut, (“1” as shown in the figure below) counter clockwise.
4.
Pull out the tip enclosure (“2” as shown in the figure below), the tip
(“3” as shown in the figure below) , and the tip stand (“4” as shown
in the figure below).
5.
Turn the front module (“5” as shown in the figure below) counter
clockwise to release it from the main body.
6.
Push out the Heating element (“6” as shown in the figure below) via
the cord (“14” as shown in the figure below).
CARE and MAINTENANCE