10
OPERATING GUIDELINES
IMPORTANT REMINDERS:
1. Make sure the equipment is placed on a flat stable surface and
all its heatgenerating components placed on their respective
holders/stands.
2. Ensure all switches are OFF prior to reworking.
3. Ensure all terminal connections are properly secured.
A. STARTUP PROCEDURE
1. Plug the device to the main power source.
2. Switch ON the device using the main power switch (item 9 on the
CONTROL PANEL GUIDE) found at the lower right portion of the
control panel.
3. The display panel will show the product name momentarily and then
“OFF” on each line of the panel, provided all function switches are
deactivated. See below for illustration.
4. The air gauge (item 1) will also appear illuminated by ample light and
the metal ball inside is at the lowest position of the visible area.
5. The system will remain in this state until a function is activated.
NOTE:
Please refer to the CONTROL PANEL GUIDE if needed.
15
C. AUTOMATE HOT AIR REWORKING
1.
Turn on the hot air gun function switch , and set to the desired
reworking temperature. Turn of hot air gun function switch.
2.
Turn on the automate function switch,”16” from the panel, Set the
time by using the up/down rework time button,”4” from the panel.
It is preset at 300 seconds.
3.
After preferred automate rework time has been set. Turn on the hot
air gun function switch.
4.
Timer would start counting down when the actual hot air
temperature has reached the set temperature. Once automate
rework time is finished, it would cool down automatically, and
display the letters “End” indicating automate process is finished.
5.
To resume manual hot air reworking depress automate function
switch.
D. SOLDERING IRON
1.
Check if the Soldering Iron is attached properly to the 6pin
receptacle and the vacuum tube is securely connected.
2.
Turn on the Power Switch.
3.
Press the Soldering Iron function switch to turn on soldering iron.
“18” from the panel.
4.
When the display shows the word “PLUG” check the connection of
the soldering iron to its receptacle.
5.
The Solder iron is set to automatically increase temperature to 249°
C upon turning on. It will show the set temperature when you are
adjusting the temperature, then it will automatically switch to
display the actual temperature when you have finished setting the
temperature.
5.
Set the temperature using the up/down Solder iron buttons ,”5”
from the panel
6.
Start using when real temperature reaches the set temperature.
OPERATING GUIDELINES