TECHNICAL SPECIFICATIONS
158 / 164 NTA47227-300A8
CALYS 50 / 75 / 100
D.2.4
Temperature by thermocouples (CALYS 50 / 75)
Sensor types:
- In accordance with CEI 584-1/1995 (couples K, T, J, E, S, B, N),
- In accordance with Din 43710 (couples U and L),
- In accordance with the ENGELHARD table (platinum couple).
- As per standard ASTM E 1751-00 (G couple)
- As per standard ASTM E 988-96 (D W3Re/W25Re couple; C W5Re/W26Re couple)
Sensor
Measuring range
Resolution
Drift / year
K
-240 to -50°C
-50 to 0°C
+0 to +1,372°C
0.2°C
0.1°C
0.05°C
0.60°C
0.10°C
0.013 % R +0.08°C
T
-240 to -100°C
-100 to 0°C
+0 to +400°C
0.2°C
0.05°C
0.05°C
0.40°C
0.10°C
0.013% R +0.08°C
J
-210 to 0°C
+0 to +1,200°C
0.05°C
0.05°C
0.20°C
0.013% R +0.07°C
E
-240 to -100°C
-100 to +40°C
+40 to +1,000°C
0.1°C
0.1°C
0.05°C
0.25°C
0.10°C
0.013% R +0.05°C
R
-50 to +350°C
+350 to +900°C
+900 to +1,768°C
0.5°C
0.2°C
0.1°C
0.5°C
0.013% R +0.35°C
0.013% R +0.2°C
S
-50 to +120°C
+120 to +450°C
+450 to +1,768°C
0.5°C
0.2°C
0.1°C
0.8°C
0.013% R +0.35°C
0.013% R +0.25°C
B
+400 to +850°C
+850 to +1,820°C
0.2°C
0.1°C
0.013% R +0.4°C
0.013% R + 0.2°C
U
-200 to 600°C
0.05°C
0.15°C
L
-200 to +900°C
0.05°C
0.20°C
C
-20 to +900°C
+900 to +2,310°C
0.1°C
0.1°C
0.25°C
0.013% R + 00.15°C
N
-240 to -190°C
-190 to -110°C
-110 to 0°C
+0 to +1,300°C
0.2°C
0.1°C
0.05°C
0.05°C
0.3°C
0.15°C
0.08°C
0.013% R +0.06°C
Platinum
-100 to +1,400°C
0.05°C
0.3°C
Mo
0 to +1,375°C
0.05°C
0.013% R +0.06°C
NiMo/NiCo
-50 to +1,410°C
0.05°C
0.013% R +0.30°C
D
+ 0 to + 310°C
+ 310 to + 1000°C
+ 1000 to + 2000°C
+ 2000 to + 2315°C
0,1°C
0,05°C
0,05°C
0,05°C
0,30°C
0,30°C
0,025% R +0,05°C
0,040% R
G
+ 0 to + 100°C
+ 100 to + 300°C
+ 300 to + 1100°C
+ 1100 to + 1800°C
+ 1800 to + 2315°C
0,5°C
0,2°C
0,05°C
0,05°C
0,05°C
2.3°C
0,55°C
0,28°C
0,4°C
0,65°C
The precision is guaranteed for a reference junction temperature of 0 °C.
When using the internal reference junction (except couple B) add an additional uncertainty of 0.3 °C at 0 °C. For other
temperatures, account must be taken of the sensitivity of the thermocouple to the temperature (T) in question, giving an
additional uncertainty of 0.3 °C * S(0 °C)/S(T).
Temperature coefficient: < 10 % of the accuracy/°C from -10°C to +18°C and from +28°C to +50 °C.
Display in °C, °F and K.
It is possible, thermocouple B excepted, to choose by programming the position of the cold junction with the keyboard:
external at 0°C,
Internal (compensation for the temperature of the terminals of the unit).
By programming the temperature.