background image

CAUTION: Wait until water is fully flowing through the heater before turning on 
the breaker.

1. Allow water to flow through the water heater unit. Allow the water to flow continuously to 
    flush out any debris as well as purge the pipes of any air.
2. Turn on the breaker to power the water heater. An audible beep will be heard and the LED 
    display will light up for 2 seconds.
3. Press       to turn ON/OFF the appliance. When the unit is ON, the LED will display the 
    water’s temperature. 30 seconds after the flow of water has been stopped the screen will to 
    into energy saving mode. The unit is still ON and the screen will still light up when a button 
    is pressed. 
    Check the product specification page to check minimum water flow for activation.
4. Press       and       to adjust the outgoing water temperature. The temperature setting ranges 
    from 86-125°F (30-52 ° C).
    

Caution:

 If the unit is paused there may be an initial burst of very hot water when resuming. 

    Please allow the water to flow for a few moments to let the temperature settle. It’s always 
    advised to test the water temperature with your hand before hopping straight into the shower.
5. Press       to convert the temperature display between Fahrenheit and Celsius.
6. The water heater unit will remember and save the previously used temperature on the next 
    use.
7. There is an over-temperature protection system for this unit. When the temperature reaches 
    149 ° F (65 ° C) the system will automatically start to decrease the temperature until it’s back 
    to a safe level. Only then will you be able to increase the temperature again.

● 

If the unit will not be used during the winter completely drain out the water to prevent freezing.

● 

Periodically clean the water heaters inlet strainer, the faucet’s aerator, and the shower’s head 

    to ensure free flow of water.

PG.10

ATTENTION

OPERATION INSTRUCTIONS

CLEANING & MANTENANCE

● 

Do not attempt to repair the water heater unit yourself. Please contact a certified professional 

or call our customer support for assistance. It is important to shut off all power to the water 
heater directly at the fuse or breaker. Failure to do so could cause permanent damage to the 
water heater and void the product warranty.

Before performing any maintenance make sure to take precaution and prevent exposure to the 

potentially hot water. The water may be hot enough to present a serious scalding hazard. The 
water should be safely drained to prevent any injury or property damage.

It is recommended to regularly maintenance the water heater. Proper maintenance will help 

lead to a long running, trouble free water heater.

Periodically remove scale and dirt that may build up at the faucet aerator.

Содержание ENVO WH-AZ011-M2

Страница 1: ...ITEM WH AZ011 M2 WH AZ146 M2 ANZZI ELECTRIC INSTANT WATER HEATER INSTALL OPERATION MANUAL V1 0 next page...

Страница 2: ......

Страница 3: ...enjoy your hot water life at its best please read and follow the installation and operation instructions carefully to ensure the long life and reliable operation of this appliance FAILURE TO DO SO CO...

Страница 4: ...ons Electrical Diagram Product Inner Structure Product Specifications Installation Guideline Installation Operation Instructions Cleaning Maintenance Trouble Shooting Packing List PG 1 PG 3 PG 3 PG 4...

Страница 5: ...o not operate the water heater again until it has been thoroughly checked by qualified service personnel When using electrical appliances basic safety precautions should always be followed including t...

Страница 6: ...r listed above or other improper operations It is extremely important to FLUSH the pipes to wash away sundries and residue in the pipes before connecting the water heater to it Risk of Fire Hydrogen g...

Страница 7: ...low meter heating chamber temp sensor Fig 1 PG 3 ELECTRICAL DIAGRAM PRODUCT INNER STRUCTURE AC240V 60Hz DISPLAY SCREEN INLET TEMP SENSOR OUTLET TEMP SENSOR FLOWMETER THERMAL CUT OUT 194 F REMARK R HEA...

Страница 8: ...gh levels of minerals and alkali can cause damage to this unit Water softening system is needed for this case Voltage 240V 240V Wattage 11000W 14600W Rated Current 47 8A 60 83A Min required circuit br...

Страница 9: ...fficient conduction for a ground Nonmetallic piping dielectric unions flexible connectors etc can cause the water heater to be electrically isolated Do not disconnect factory ground It is recommended...

Страница 10: ...y saving or other unapproved devices other than those authorized by ENVO into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the wat...

Страница 11: ...on position for the water heater 2 Place template provided on wall and use pencil to mark screw hole locations Make sure the outlet and inlet pointed downward vertically If screw locations are in wall...

Страница 12: ...hread protectors 1 2 ATTENTION Connect the inlet cold water line to the cold inlet fitting on water heater Connect the outlet hot water line to the hot outlet fitting on water heater Use two wrenches...

Страница 13: ...uit 2 Connect the cable to the breaker Install L1 red wire to L1 L2 black wire to L2 and E green yellow wire to Ground Make sure that the metal wire ends and the breaker are well connected Then tighte...

Страница 14: ...will remember and save the previously used temperature on the next use 7 There is an over temperature protection system for this unit When the temperature reaches 149 F 65 C the system will automatic...

Страница 15: ...d another wrench to tighten the connecting pipes SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTIONS Inlet and outlet fittings leaking LED no signal Water too hot Water too cold LED shows E1 LED shows E3 Out...

Страница 16: ......

Отзывы: