Electrical Connections

PG.9

ATTENTION

INSTALLATION

1. Open the shut-off valve to allow water to flow 
into the water heater.
2. Check for any leaks at plumbing connections.

If there is any leaks from the nipples, hand 
tighten them then tighten with wrench. DO NOT 
over tighten.

 3. Open several hot water fixtures to allow 
water to run through the water heater to purge 
air from the water lines. Failure to purge air 
from the water lines can cause permanent 
damage to the heating elements. 
4. Check again for any leaks at plumbing 
connections. Correct any that are found.

1.Turn the power off at the fuse or circuit. 
2. Connect the cable to the breaker. 
Install L1 (red wire) to L1, L2 (black wire) to 
L2, and E (green-yellow wire) to Ground. 
Make sure that the metal wire ends and the 
breaker are well connected. Then tighten 
the screws to secure the wires. 
See ELECTRICAL DIAGRAM on PG.3 for reference.

1.Make sure that the breaker is switched OFF before installing the wires 

to avoid any danger of electric shock. All mounting and plumbing must 

be completed before proceeding with electrical connection.

2.The heater must be connected to its own independent electrical circuit. 

Install a fuse box or switch ("breaker") for exclusive use of the heater.

3.All unit must be connected to a properly grounded dedicated branch 

circuit with proper voltage rating.

4

Fig 7

Nipple

Circuit Breaker

L2

BLACK

L1

RED

 

G

R

O

U

N

D

E

GREEN-YELLOW

Содержание ENVO WH-AZ011-M2

Страница 1: ...ITEM WH AZ011 M2 WH AZ146 M2 ANZZI ELECTRIC INSTANT WATER HEATER INSTALL OPERATION MANUAL V1 0 next page...

Страница 2: ......

Страница 3: ...enjoy your hot water life at its best please read and follow the installation and operation instructions carefully to ensure the long life and reliable operation of this appliance FAILURE TO DO SO CO...

Страница 4: ...ons Electrical Diagram Product Inner Structure Product Specifications Installation Guideline Installation Operation Instructions Cleaning Maintenance Trouble Shooting Packing List PG 1 PG 3 PG 3 PG 4...

Страница 5: ...o not operate the water heater again until it has been thoroughly checked by qualified service personnel When using electrical appliances basic safety precautions should always be followed including t...

Страница 6: ...r listed above or other improper operations It is extremely important to FLUSH the pipes to wash away sundries and residue in the pipes before connecting the water heater to it Risk of Fire Hydrogen g...

Страница 7: ...low meter heating chamber temp sensor Fig 1 PG 3 ELECTRICAL DIAGRAM PRODUCT INNER STRUCTURE AC240V 60Hz DISPLAY SCREEN INLET TEMP SENSOR OUTLET TEMP SENSOR FLOWMETER THERMAL CUT OUT 194 F REMARK R HEA...

Страница 8: ...gh levels of minerals and alkali can cause damage to this unit Water softening system is needed for this case Voltage 240V 240V Wattage 11000W 14600W Rated Current 47 8A 60 83A Min required circuit br...

Страница 9: ...fficient conduction for a ground Nonmetallic piping dielectric unions flexible connectors etc can cause the water heater to be electrically isolated Do not disconnect factory ground It is recommended...

Страница 10: ...y saving or other unapproved devices other than those authorized by ENVO into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the wat...

Страница 11: ...on position for the water heater 2 Place template provided on wall and use pencil to mark screw hole locations Make sure the outlet and inlet pointed downward vertically If screw locations are in wall...

Страница 12: ...hread protectors 1 2 ATTENTION Connect the inlet cold water line to the cold inlet fitting on water heater Connect the outlet hot water line to the hot outlet fitting on water heater Use two wrenches...

Страница 13: ...uit 2 Connect the cable to the breaker Install L1 red wire to L1 L2 black wire to L2 and E green yellow wire to Ground Make sure that the metal wire ends and the breaker are well connected Then tighte...

Страница 14: ...will remember and save the previously used temperature on the next use 7 There is an over temperature protection system for this unit When the temperature reaches 149 F 65 C the system will automatic...

Страница 15: ...d another wrench to tighten the connecting pipes SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTIONS Inlet and outlet fittings leaking LED no signal Water too hot Water too cold LED shows E1 LED shows E3 Out...

Страница 16: ......

Отзывы: