Software functions
7-18
7.4 Web functions
The B2G78-E1 is equipped with a web server and various settings can be carried out through a web
browser.
The following login screen appears when accessed with a browser.
Basic settings of the B2G78-E1 can be carried out via the web server.
The default IP address is 192.168.0.36.
Connect the PC to be used for setting directly to the B2G78-E1 with a LAN cable. Either a cross or
straight LAN cable is acceptable.
Set the connected LAN interface as follows.
IP address: 192.168.0.xx (Excluding 36, 0, and 255 for xx)
Sub-net mask: 255.255.255.0
Turn on the main unit power. It is accessible when the "RDY" LED lights up and "LINK.B" flashes.
Start a web browser (such as IE) and access the set IP address. Enter http://192.168.0.36
in the
address bar of the browser and press the Enter key.
The following login screen appears.
Enter ID: anywire, Password: anywire.
The following screen (process setting screen) appears.