background image

-BSK4117M**1K  5/9-

[How to connect]

[Installation Examples]

Use the toothed washer when affixing.
Tightening torque: 5.9N

m

φ

12.5

- Installation hole 
  radius

Setting port

Use the toothed washer when affixing.
Tightening torque: 15N

m

φ

18.5

- Installation hole 
  radius

Setting port

Use the toothed washer when affixing.
Tightening torque: 59N

m

φ

30.5

- Installation hole 
  radius

Setting port

<BS-K4117-M12-1K>

<BS-K4117-M18-1K>

<BS-K4117-M30-1K>

Red: DP (+)
Black: DN (-)

Connect to the AnyWireASLINK transmission line (DP, DN).
DP and DN have polarity, so be sure to connect correctly.

Example of mounting an LP connector to the end of the transmission line

Applicable LP connector: LP2-PWH-10P (2P), LP4-WW-10P (4P)

Transmission line

UL style 2103
Two cores of No.24 AWG (black) 

φ

4.1

Core line finished 
outside diameter

φ

1.5

2  1

A

B

C

Cover

Hole to pass clamp through

Clamp

① ②

⑤ ⑥

③ ④

Dedicated tool: LP-TOOL

Example for BS-K4117M-M18-1K

* The following explanatory figure is an example for the LP2-PWH-10P.

Place the lines in the groove so that the black line 
(DN) is positioned nearer the hinge side (pin 1) of 
the cover, and fold part A onto the part B side, and 
then hitch the hook C to fix the cover.

Insert the body clamp into the hole 
of the cover and crimp them with a 
dedicated tool.

For the LP4-WW-10P, perform crimping with pin 1 for DN, pin 2 for DP, and 
pins 3 and 4 empty.

After crimping, check 
that the hooks 

 to 

 

are securely engaged.

With cover mounted
Check that the hooks 

 

and 

 are engaged.

[Installation Location]

[Precautions for Use]

If you expect you will change the settings, install the unit so that the setting 
port is visible.

CAUTION

When affixing this product, provide enough slack so that cables and connection 
connectors are not stressed.
Do not over-tighten screws. Doing so may cause a failure.

- Location where this product is not directly subject to vibration or shock
- Location without condensation
- Location where the atmosphere is free of corrosive gas, flammable gas, and 

sulfur

- Location far from high-voltage or high-current cables
- Location far from cables and controllers that generate servo, inverter, or other 

high-frequency noise

- Location away from direct sunlight

- This unit is to be used connected to an AnyWireASLINK transmission line.

It will not operate if it is directly connected to the sequence I/O card or the like.

- Use with an appropriate voltage range.
- Include the transmission line provided with this product in the total line length.

Содержание ASLINKSENSOR BS-K4117-M 1K Series

Страница 1: ...circuit or similar problem in the hybrid unit including the output unit and the output circuit may result in smoke generation or fire An external safety device such as a fuse must be installed System power supply Use a stabilized 24V DC power supply Use of a non stabilized power supply may cause problems with the system Separately route high voltage and power cables Although the AnyWireASLINK has ...

Страница 2: ...for the AnyWireASLINK according to the load current This Products Guide describes a two wire non isolated terminal If the load current is small using a two wire non isolated terminal allows for achieving simplified wiring without a local power supply If you are prioritizing the sites of concentrated loads or the number of units connected hybridization with a four wire isolated terminal which suppo...

Страница 3: ... EAC 06 472 MAX 6A 24V DC Model Type Allowable power current Filter allowable power current Insert the ASLINK filter Type ANF 01 regardless of installation method and distance when complying with CE Standard General purpose power supply filter Use if necessary General purpose power supply filter Use if necessary POWER IN SLAVE The figure is an explanatory schematic Adjust the actual terminal layou...

Страница 4: ...re terminal Four wire terminal DP DN 24V 0V Four wire terminal Four wire terminal DP DN 24V 0V Four wire terminal DP DN 24V 0V Four wire terminal 24V 0V 24V 0V PE AnyWireASLINK master 24V 0V L N FG 24V DC stabilized power supply 24V 0V 24V 0V PE DP DN 24V 0V Four wire terminal DP DN 24V 0V Four wire terminal A B General purpose power supply filter Use if necessary General purpose power supply filt...

Страница 5: ...and then hitch the hook C to fix the cover Insert the body clamp into the hole of the cover and crimp them with a dedicated tool For the LP4 WW 10P perform crimping with pin 1 for DN pin 2 for DP and pins 3 and 4 empty After crimping check that the hooks to are securely engaged With cover mounted Check that the hooks and are engaged Installation Location Precautions for Use If you expect you will ...

Страница 6: ...etting is changed in the WRITE mode the setting is reflected after the system is re started up When setting is changed in the DIRECT WRITE mode the setting is reflected at the time when the writing is completed If this unit is included in a parallel arrangement use the remote head ARW RH together and ensure that writing is not performed to terminals not intended Make sure to use a 24V DC stabilize...

Страница 7: ...timer ON delay timer enabled OFF delay timer enabled Address writer ARW 04 ARW 03 Parameter 10 Default 0 Set the ON delay timer OFF delay timer 0 255 Default 0 Address writer ARW 04 ARW 03 Parameter 11 Normally open Normally close setting Variable Details 0 Normally open ON with work present Set the normally open normally close 1 Normally close ON with work absent Alarm value Hi setting Alarm valu...

Страница 8: ...as shown below ASLINKSENSOR is not connected to an AnyWireASLINK system Power supply for the AnyWireASLINK system itself is not turned on Directly connected to 24 0V power supply The ASLINKSENSOR maintains the address number 255 default setting The ASLINKSENSOR has an address redundant with another unit Transmission signal level reduction has been detected The sensing level has been reduced Confir...

Страница 9: ...2017 UMA 16717A EN Outside Dimensions Unit mm BS K4117 M18 1K BS K4117 M12 1K BS K4117 M30 1K Transmission cable Oil resistant flex resistant type φ29 24 1000 15 5 35 4 10 17 M18X1 Red DP Black DN Transmission cable Oil resistant flex resistant type Red DP Black DN φ21 17 35 5 3 10 15 4 1000 11 M12X1 10 5 Red DP Black DN M30X1 5 43 36 φ42 17 6 1000 Transmission cable Oil resistant flex resistant t...

Отзывы: