-L*A1AW  1/11-

[Function]

[Included items]

[Name of each part]

LA-A1AW (Base)
LB-A1AW (Extension)

Base unit ...1
Base unit ...1

ASLINKAMP

Voltage: 0-10V, 0-5V, 1-5V
Current: 4-20 mA, 0-20 mA

Measurement 
input range

Resolution

1/16000

Model

Insulated

CH insulated

Expansion connector

Analog port 
e-CON (3P)

LED display

7-segment display

Protective cover

LED display

7-segment display

Protective cover

Transmission line

Analog port 
e-CON (3P)

Functions

Input specifications setting
Reference point shift mode
Average number of moving times
Address/parameter automatic setting (Base unit only)
Miniature

AnyWireASLINK System Products Guide

ASLINKAMP 

[Analog Input Unit (CH insulated type with 7-segment)]

L

-A1AW

[Notes on Safety]

A WARNING indicates a potentially hazardous situation which, if not 
handled correctly, could result in death or serious injury.

A CAUTION indicates a potentially hazardous situation which, if not 
handled correctly, may result in personal injury or property damage.

[Warranty]

[Type]

WARNING

CAUTION

Precautions that must be observed in order to use this system safely are 
indicated as shown below. You must observe these precautions.

 Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) 
year after the delivery thereof to a location as designated by the original owner.

 Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty 
period when it is used normally in accordance with the specifications described 
in this User's Manual, the Company shall replace or repair the defect free of 
charge, except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner; 
[2] Fault caused by cause other than the delivered Product;
[3] Unauthorized modification or repair of the Product by any party other than 

the Company;

[4] Any unusual force of nature, disaster, or other cause beyond the Company's 

control.

The term "warranty," as used herein, refers to the warranty applicable to the 
delivered product alone. The Company shall not be liable for any damages 
consequential or incidental to a malfunction of the delivered product.

 Repair at cost

After the expiration of the warranty period, any troubleshooting or repairs shall 
be done at the expense of the owner.
Even during the warranty term, any repairs and troubleshooting for defects 
arising from causes outside the scope of the warranty as specified above shall 
be done at the owner's expense.

LA-A1AW

1CH (Base unit)
1CH (Extension unit)

Analog input unit

(CH insulated type 

with 7-segment)

LB-A1AW

Bit operation

CAUTION

WARNING

 System Safety

This system is intended for general industrial applications. It does not 
have functions for supporting applications requiring higher levels of safety 
such as safety-related devices or accident prevention systems.

 Always turn off the system power before attempting to mount or replace.

 Prolonged continuous flow of a rated load current or higher or a transit 

current due to load short-circuit or similar problem, in the hybrid unit 
including the output unit and the output circuit may result in smoke 
generation or fire. An external safety device such as a fuse must be 
installed.

 System power supply

Use a stabilized 24V DC power supply. Use of a non-stabilized power 
supply may cause problems with the system.

 Separately route high-voltage and power cables

Although the AnyWireASLINK has a high noise margin, lay the 
transmission lines and I/O cables so as to keep them away from 
high-voltage and power cables.

 Connectors and terminals

 Pay careful attention to the length and installation of cable wiring to 

ensure that connectors and cables are neither stressed nor 
disconnected even if they are stressed.

 Make sure to prevent any metal objects from getting inside the 

connectors or the terminal blocks.

 Short-circuits caused by metal objects or mis-wiring are likely to 

damage the device.

 Do not impose any external loads on the units.

Doing so may cause a failure.

 Do not disconnect or reconnect between the transmission line and slave 

units when a transmission line is operating.
A malfunction may occur.

 Use the AnyWireASLINK within the range of the specifications and 

conditions shown below.

Extension

Base

Содержание ASLINKAMP L-A1AW Series

Страница 1: ...mpany shall not be liable for any damages consequential or incidental to a malfunction of the delivered product Repair at cost After the expiration of the warranty period any troubleshooting or repair...

Страница 2: ...ator BT0 polar to the terminal on the transmission line farthest from the AnyWireASLINK master Supply current on the transmission line DP DN Total length 50m or less 1 25mm2 0 75mm2 MAX 2A MAX 1 2A MA...

Страница 3: ...24V DC stabilized power supply Two wire terminal Four wire terminal 24V 0V 24V 0V PE AnyWireASLINK master General purpose power supply filter Use if necessary If any of the side by side lines of DP D...

Страница 4: ...V 0V Four wire terminal A B 24V 0V 24V 0V PE Filter notation in the drawing General purpose power supply filter Use if necessary General purpose power supply filter Use if necessary LOAD LINE EAC 06 4...

Страница 5: ...unit Refer to P6 Decide the maximum number of extended devices within the range meeting the conditions below Extension Base Example 1 Considering based on the limit of I O points LA A1AW Input 16 poi...

Страница 6: ...it is not used Example of local power supply To LP4 WW 10P crimped transmission line link connector FK4 125 100 LP4 WR 10P DP DN 24V 0V Master unit Master unit A D Circuit A D Circuit Control circuit...

Страница 7: ...DP DN of the terminal 2 Setting is required for all AnyWireASLINKs devices Open the protection cover of the set analog input unit and direct the address writer to the setting port of the unit as show...

Страница 8: ...Ex During 12 mA conversion LINK V mA ALM LINK V mA ALM About 3 seconds Display example during operation L A1AW 8 12 Data Structure Before shipment 0 Reference point shift mode 14 15 Conversion data 1...

Страница 9: ...he AnyWireASLINK system and turn on the power Re connect to the AnyWireASLINK system The ASLINKAMP maintains the address 255 default setting Set any address other than 255 The ASLINKAMP has an address...

Страница 10: ...00 16200 0 Over the upper limit value 200 Under the lower limit value 0 Over the upper limit value 200 Under the lower limit value 16000 16200 0 Over the upper limit value 200 3 8mA 0 95V 0 2mA Under...

Страница 11: ...5Vp p max 512 max IN 256 OUT 256 Up to 128 units Bus type Multi drop method T branch method Tree branch method Connection mode Transmission line disconnection transmission line short circuit transmiss...

Страница 12: ...2 Address Anywire Corporation Contact by mail Contact info_e anywire jp Contact by website http www anywire jp Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Printed in Japan 2016 2017 U...

Отзывы: