6.5
Network Configuration Object (04h)
Category
Basic
Object Description
This object contains network specific configuration parameters that may be configured by the end user.
Supported Commands
Object:
Get_Attribute (01h)
Reset (Factory Default) (05h)
Instance:
Get_Attribute (01h)
Set_Attribute (02h)
Object Attributes (Instance #0)
#
Name
Access
Type
Value
1
Name
Get
Array of CHAR
“Network Configuration”
2
Revision
Get
UINT8
01h
3
Number of instances
Get
UINT16
0002h
4
Highest instance no.
Get
UINT16
0002h
Instance Attributes (Instance #1, Device Address)
Basic
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Device Address”
2
Data type
Get
UINT8
04h (= UINT8)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
UINT8
Value:
Meaning:
1... 127:
CANopen device address value
255
Enforce LSS at startup
(Note that this value may be updated by the LSS service, see
Layer Setting Services (LSS), p. 13
)
Anybus
®
CompactCom
™
30 Network Guide