Basic Operation
13 (36)
4.3
Device Address & Baud Rate Configuration
4.3.1
General
The CANopen baud rate and device address can be set by the host application using Network
Configuration Object (04h). Note that in order to ensure network compliance, the recommenda-
tions stated for this object in the Anybus CompactCom 30 Software Design Guide must be fol-
lowed at all times.
The module supports automatic baud rate detection, i.e. if no valid baud rate is set, the module
will measure the bus traffic at different speeds until the correct baud rate has been established.
Under normal conditions, i.e. with cyclic bus traffic above 2 Hz, the baud rate should be de-
tected within 5 seconds. Note that the automatic baud rate detection will not work if there is no
traffic on the network.
4.3.2
Layer Setting Services (LSS)
The module supports the Layer Setting Service (LSS). This service can be used to set the Baud
Rate and Device Address via the network, and may address the module by its Vendor-ID, Prod-
uct Code, Revision number and serial number.
It is possible to enforce LSS during startup by setting the instance Device Address (01h) to 255,
see
Network Configuration Object (04h), p. 24
4.4
Network Reset Handling
4.4.1
Reset Node
Upon receiving a Reset Node request from the network, the module will issue a reset command
to the Application Object (FFh) with CmdExt[1] set to 00h (Power-on reset) and shift to the Any-
bus state EXCEPTION. The bus interface is shifted into a physically passive state.
4.4.2
Reset Communication
Upon receiving a Reset Communication request from the network, the module will reset all
Communication object entries to their default values, and shift to the CANopen state Reset
Communication. No reset command will be issued to the host application.
4.4.3
Restore Manufacturer Parameters to Default
Upon receiving a Restore Manufacturer Parameters to Default request from the network, the
module will issue a reset command to the Application Object (FFh) with CmdExt[1] set to 01h
(Factory default reset).
See also
Standard Objects, p. 14
, entry 1011h (Restore Parameters)