background image

P/N 1011512 Rev A 10/18

15

Part #

Description

7001629

Knob kit

7001630

Plunger Assy kit

7001631

Male to Barb Elbow kit

7001632

Male to Male Elbow kit

7001633

Generator kit

7001634

Vane Micro Switch kit

7001635

Vane Switch Lever kit

7001636

Front Housing Micro Switch kit

7001637

PCB-Assy Switch Board kit

7001638

Terminal Block kit

7001639

Control board kit

7001661

Cup

7001662

Steam nozzle

7001663

Cup mounting platform

7001664

Hose connection manifold

7001665

 Cup and steam nozzle kit

7001666

Cup, nozzle, and cup mounting platform kit

7001667

Complete accessory kit:

     1 - cup

     1 - steam nozzle

     1 - cup mounting platform

     1 - hose connection manifold

Содержание JS-1000

Страница 1: ...N 1011512 Rev A 10 18 Jet Steamer International Owner s Manual JS 1000 IPX3 Rating Manufacturing Number 9100672 Original Instructions www antunes com CAUTION Read the instructions before using the machine ...

Страница 2: ...tact Antunes Customer Service immediately at 1 877 392 7856 toll free Fill in the information in the next section and have it ready when calling for assis tance The serial number is on the specifi cation sticker located on the system Equipment Information to Save Purchased from Date of purchase Model number Serial number Manufacturing number Authorized Service Agency Name Phone No Address Table of...

Страница 3: ... is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction y y Children being supervised are not to play with the appliance y y Bread may burn Therefore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain saf...

Страница 4: ...odel A Width B Depth C Height 9100672 12 5 318mm 20 75 527mm 20 508mm Mfg No Volts Watts Amps Hertz Plug Description Plug Configuration 9100672 208 240 3800 19 60 HRMN IEC 309 P N 0700588 Assembly Only Electrical Ratings Specifications ...

Страница 5: ...gula tor to the cold water line 11 Direct the drain hose to a drain Al low a 2 inch gap between the drain hose and the drain Do NOT allow the drain hose to be submerged Equipment Setup When placing the unit into service pay attention to the following guidelines y y Make sure power is off and the unit is at room temperature y y Do NOT block or cover any openings on the unit y y Do NOT immerse cord ...

Страница 6: ...ontrolled by a normally closed solenoid valve located inside the steamer s electrical housing 1 Turn off the water valve not supplied that provides water to the unit 2 Connect the 1 4 6 5 mm ID flexible tubing to the outlet side of the water pressure regulator and secure using the worm clamp NOTICE A Water Pressure Regulator must be installed Failure to do so will result in poor steaming and possi...

Страница 7: ...e If the food item you are cooking is already shown on the display you can simply press it 6 The unit begins the cooking cycle The display shows the time remain ing in the cooking cycle and beeps when cooking is complete 7 When cooking is complete the unit returns to the Ready screen 8 Remove the cup from the unit and continue with food preparation as required Power button Touchscreen display Figu...

Страница 8: ...yed onto the steam generator y y Shot Rate The time between each shot of water onto the steam generator y y Shot Count This value is automatically calculated by the system using the Cycle Time and Shot Rate values This is the number of total shots of water that will occur during the cook cycle for that menu item The shot count can only be changed by adjusting the Cycle Time or Shot Rate values You...

Страница 9: ... press the radio button next to each setting before you can adjust it 5 Once you have changed the System settings as desired press the Save icon The system saves the changes to memory To cancel your changes press the Cancel icon to return to the Tools screen Loading Menu Data via USB The steamer is equipped with a USB in terface on the side of the unit see Figure 4 This allows you to load menu ite...

Страница 10: ...TICE You do not need to wait until the cool down mode completes However the unit will be hot so wear heat resistant gloves dur ing cleaning 3 Wearing heat resistant gloves remove the components highlighted in Figure 5 4 Wash rinse and sanitize those com ponents at the sink or in the dishwash er Allow them to air dry 5 Wipe the exterior of the unit with a clean sanitized towel Clean up any spills c...

Страница 11: ...Knobs see Figure 6 This allows the Generator Mani fold to be opened 4 Use a flat blade screw driver to gently pry up the Generator Manifold and remove it 5 Inspect the Generator Manifold and Generator Figure 5 If mineral deposits have formed place a flat blade screwdriver into openings Use a twisting motion to scrape openings clean NOTICE If the mineral deposits come off in flakes or in layers bui...

Страница 12: ...Authorized Service Agency for service Unit displays system error Database Failure Possible data corruption on the receipts Do a factory reset from the Menu Items menu to reset stored receipts Reenter any missing receipts Unit heats but little or no steam is produced and or the product requires more steaming than usual Water line valve is closed Verify that the water line valve is open Strainer is ...

Страница 13: ...P N 1011512 Rev A 10 18 13 WIRING DIAGRAM ...

Страница 14: ...cription Qty 42 0200379 Gasket 1 43 0507800 Gasket retainer 1 44 0400290 Electrical insulator 2 45 1002730 Wiring diagram label 1 46 0507960 Rear panel 1 47 3060130 Nut hex KEPS 06 32 steel zinc plated 2 48 0508575 Quick disconnect mount 1 49 2080117 Quick disconnect 1 8 NPT 1 50 4040145 Solenoid valve 24 VAC 1 51 2140159 Teflon tape 1 4 1 52 2190179 Elbow 1 8 NPT x 3 16 barb 1 53 0700588 Power co...

Страница 15: ...ch Lever kit 7001636 Front Housing Micro Switch kit 7001637 PCB Assy Switch Board kit 7001638 Terminal Block kit 7001639 Control board kit 7001661 Cup 7001662 Steam nozzle 7001663 Cup mounting platform 7001664 Hose connection manifold 7001665 Cup and steam nozzle kit 7001666 Cup nozzle and cup mounting platform kit 7001667 Complete accessory kit 1 cup 1 steam nozzle 1 cup mounting platform 1 hose ...

Страница 16: ... 9 8 12 11 10 15 26 25 27 53 54 48 55 59 60 63 66 65 64 14 69 70 67 73 72 58 57 56 71 74 75 76 77 78 68 18 19 21 24 23 22 7 20 17 50 49 51 52 13 28 29 30 31 32 33 34 35 39 36 38 37 40 79 80 81 47 81 83 82 82 21 61 62 47 42 43 47 46 45 44 41 7 ...

Страница 17: ...P N 1011512 Rev A 10 18 17 Notes ...

Страница 18: ...cover water con tamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Antunes reserves the right to make changes in design...

Отзывы: