P/N 1011556 Rev A 08/19
®
Unpacking
1.
Open the large box. It should contain:
a. Filter Head w/ Bracket
b. Wall Bracket Standoff
c. Filter Cartridge
d. Carbonate Hardness Test Kit
e. Flush Valve
f. Fitting Pack
2.
Remove all packing materials and protective coverings
from the system.
NOTE:
If any parts are damaged, contact Antunes
IMMEDIATELY at +1-877-392-7854.
The threads on the filter head are straight pipe male BSP
threads. A water-tight seal is made on a gasket between the
inlet or outlet fitting and the head.
The fitting kit contains:
Qty 2 3/8" BPS female by 3/8" OD Tube Adaptors
Qty 2 3/8" OD tube stem by 1/2" ID Hose Adaptors
Make sure the black gasket is in place at the bottom of the
female thread before attaching the fitting to the head.
CAUTION
Do not use pipe tape or pipe dope on the pipe threads!
Only hand-tighten BSP threaded fittings. Do not over-tighen
fittings. Fittings could break if overtightened.
Do not use a wrench on the BSP fittings.
CAUTION
Only hand-tighten BSP threaded fittings.
Equipment Setup
Plumbing
NOTE:
The system must be connected to the COLD water
line. DO NOT connect the system to the hot water
line.
The system uses the following connections:
System Inlet
3/8" OD Tube or 1/2" ID Hose
System Outlet
3/8" OD Tube or 1/2" ID Hose
DO NOT over tighten the connections. Use plastic fittings when
connecting to the plastic connections of the system.
If soldered plumbing is used, DO NOT apply heat to, or near,
the filtration system. Use union (O-Ring seal) connections for
ease of installation and future servicing.
Suggested Tools and Supplies for Installation
The following tools and supplies are suggested to help with the
installation:
y
Screwdriver
y
Two Gallon Bucket
y
Drill with Bits
y
Level
y
Tape Measure
y
Fresh, Unscented Liquid
Chlorine Bleach
Inlet Water Plumbing
Before connecting the fitting to the System Inlet, the plumbing
to the system must be flushed clear of all debris. Hold a bucket
at the inlet water line and slowly open the Inlet Water Valve.
Allow the pipe to flush until all debris is removed.
NOTE:
The system can be mounting either vertically or
horizontally. Allow space below the cartridge for
changeout (Figure 4).
Figure 3. System Components
Figure 4. Mounting the System
mind. 2.56 in
mind. 2.56 in
Flush Valve
Wall Bracket
Standoff
Carbonate Hardness
Test Kit
3/8" BPS x 3/8"
OD Tube Adaptor
Flush Valve
Hose
Filter Head
Cartridge
Wall Bracket
Содержание HRS-200