Safety Information

Installation

 

y

Read and understand all instructions 

before installing or using the unit.

 

y

Install and locate the equipment only for its 

intended use as described in this manual.

 

y

This equipment is to be installed to comply with the 

local plumbing code and any other applicable code.

 

y

This equipment should be supplied 

with only cold water.

 

y

Water pressure must not exceed 100 psig (690 

kPa). To reduce water pressure, install a water 

pressure regulator and set to suit the application.

 

y

When installed on metallic plumbing, a properly 

sized electrical bonding jumper must be installed 

across the inlet and outlet pipes serving this unit.

 

y

For installations in Massachusetts, the 

Commonwealth of Massachusetts Plumbing 

Code 248 CMR shall be adhered to. The 

use of saddle valves are not permitted. 

Please consult your local plumber.

NOTE:

 If the inlet water pressure is less than 50 psig 

(345 

kPa), it is recommended that a suitably-

sized booster system (outlet pressure 60 psig 

- 100 psig max (414 kPa - 690 kPa max) be 

installed.

Operation

 

y

DO NOT operate the unit if it has been damaged 

or dropped, or if it is not working properly.

 

y

DO NOT block or cover any 
openings on the equipment.

Maintenance

 

y

DO NOT use corrosive chemicals in this equipment.

 

y

DO NOT clean the unit with a 

water jet or steam cleaner.

Service

 

y

This equipment should be serviced by qualified 

personnel only. Contact Antunes for repair.

Safety Information (Continued)

Protect from freezing

If the filter freezes during operation or storage, irreversible 

damage and brittle cracking of the cartridge or housing may 

result.

Protect from direct sunlight or other UV sources

Avoid long-term exposure to direct sunlight or other UV  

sources. 

Protect from high temperatures or abrupt variation in 

temperature

The maximum operating temperature is 86°F (30°C). Avoid 

abrupt variations in temperature. Any temperature variation 

should be made slowly.

Protect from rough handling or dropping

Mechanical damage, external breakage, and/or internal 

breakage of the filter can result if the system is dropped or 

bumped. Handle with care at all times during transportation 

and installation.

Protect from organic solvents and concentrated acids

Prevent any and all contact of the filter with strong solvents, 

solvents containing chlorine, or concentrated acids. DO NOT 

use strong solvents or concentrated acids on any plastic parts 

of the filter system. Examples of some solvents to avoid: 

acetone, methyl acetate (nail polish remover); hexane (spot 

removers); turpentine, toluene (paint thinners); dry cleaning 

solutions, insecticides.

Protect from abrasive material

The filter must be protected from abrasive materials like 

shavings left in a pipe. Abrasive materials in contact with the 

filter can cause irreversible damage. All pipes must be flushed 

clean before installing the filter. All plastic parts of the filter 

system must be protected from sharp objects like knives, 

sand paper, or other tools. Cutting or nicking a plastic part can 

weaken it and cause a leak. DO NOT use abrasive cleansers 

on any plastic parts.

Protect from water hammer

The system must be protected from shock, pressure surges, 

or pulsation that may occur inside water pipes. Water 

hammer occurs in pipes when a valve or faucet shuts quickly. 

Install a water hammer arrestor (pressure vessel containing 

compressed air separated from the water by a diaphragm) to 

reduce pressure shock.

CAUTION

This equipment is to be installed to comply with the 

basic plumbing code of the Building Officials and Code 

Administrators, Inc. (BOCA) and the Food Service Sanitation 
Manual of the Food and Drug Administration (FDA).

CAUTION

Water Flow Regulator Assemblies are NOT interchangeable. 
Operating the system with the wrong Water Flow Regulator 
or without a regulator can damage the system, cause 
personal injury, and voids the warranty!

Содержание HRS-200

Страница 1: ...andard 42 for the reduction of Chlorine Taste and Odor Owner s Manual Original Instructions Manufacturing Numbers 9700562 www antunes com CAUTION Read all instructions before using the unit Original Instructions P N 1011556 Rev A 07 19 HARDNESS REDUCTION SYSTEM HRS 200 ...

Страница 2: ...g the system Your system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ensure dependable trouble free operation In Case of Damage If the unit arrives damaged file a claim with the carrier immediately Save all packing materials when filing a claim Freight damage claims are the responsibility of the purc...

Страница 3: ... maximum operating temperature is 86 F 30 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping Mechanical damage external breakage and or internal breakage of the filter can result if the system is dropped or bumped Handle with care at all times during transportation and installation Protect from organic solvents and conce...

Страница 4: ...4 185 mm 23 5 8 600 mm Weight Cartridge Dry 16 5 lb 7 5 kg Cartridge Wet 24 25 lb 11 0 kg Model Drain must accommodate flow up to 9700562 HRS 200 1 gpm Model Replacement Cartridge 9700562 HRS 200 7000967 Cartridge HRS 200 System Inlet System Outlet 3 8 OD Tube or 1 2 ID Hose 3 8 OD Tube or 1 2 ID Hose B C A Figure 1 Cartridge Dimensions ...

Страница 5: ...onditions actual performance may vary DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Performance Data Sheet Filter Cartridge Capacities Minimum Operating Pressure 29 psig 200 kPa Maximum Operating Pressure 11...

Страница 6: ...h activated carbon to reduce chlorine taste and odors Figure 2 Water then passes through the ion exchange resin reducing the carbonate hardness Depending on the filter head blend setting some of the water that enters the cartridge may bypass the ion exchange resin This bypass water passes through the activated carbon for taste and odor reducton before mixing with the carbonate hardness reduced wat...

Страница 7: ...nnect the system to the hot water line The system uses the following connections System Inlet 3 8 OD Tube or 1 2 ID Hose System Outlet 3 8 OD Tube or 1 2 ID Hose DO NOT over tighten the connections Use plastic fittings when connecting to the plastic connections of the system If soldered plumbing is used DO NOT apply heat to or near the filtration system Use union O Ring seal connections for ease o...

Страница 8: ...he Flush Valve to the valve outlet 6 Attach the Water Meter if available to the outlet of the Flush Valve finger tight only 7 Attach an adaptor to the outlet of the Water Meter if available finger tight only 8 Connect the inlet to the water supply It is recommended that an inlet shut off valve not provided be installed ahead of the filter system 9 Connect the outlet of the filter system to the wat...

Страница 9: ...ss Set the blend Figure 9 based on the determined carbonate hardness and referring to the appropriate use in the Tables on pages 12 and 13 There are four possible settings for the blend Figure 10 The blend can be changed easily by twisting the cap on top of the filter head Turn the cap either clockwise or counter clockwise until the mark on the head points to the blend number Allow the cap to snap...

Страница 10: ...sanitizer is present 7 Close the faucet or tap 8 Let the system stand without water flow for at least 15 minutes to allow the sanitizer to sanitize the plumbing 9 After 15 minutes without water flow open the faucet or tap and allow water to flow through the system until the presence of sanitizer is gone Open all other faucets or taps in line with the system to flush any remaining sanitizer from th...

Страница 11: ...hed completely Heater boiler are not enough protected against lime scale Wrong chosen blend setting filter capacity is reached passed Check the hardness blend setting and the filter capacity Water meter display flashing Gallon capacity has been exceeded Change filter cartridge reset meter Water meter display flashing low battery Battery needs replacing Replace battery in meter Drinking water is fo...

Страница 12: ...3 1 585 6 000 445 25 2 1 364 5 164 463 26 2 1 312 4 966 481 27 2 1 263 4 782 499 28 2 1 218 4 611 517 29 2 1 176 4 452 534 30 2 1 137 4 303 534 30 2 1 034 3 912 ppm CaCO3 Grains per US gallon GPG Blend setting Filter capacity HRS 200 US gallons Liters 71 4 3 7 926 30 000 89 5 3 6 341 24 000 107 6 3 5 284 20 000 125 7 3 4 529 17 143 143 8 3 3 963 15 000 161 9 3 3 523 13 333 178 10 3 3 170 12 000 19...

Страница 13: ... 3 793 445 25 1 962 3 641 463 26 1 925 3 501 481 27 1 891 3 371 499 28 1 859 3 251 517 29 1 829 3 139 534 30 1 802 3 034 534 30 1 729 2 758 ppm CaCO3 Grains per US gallon GPG Blend setting Filter capacity HRS 200 US gallons Liters 71 4 0 5 466 20 690 89 5 0 4 373 16 552 107 6 0 3 644 13 793 125 7 0 3 124 11 823 143 8 0 2 733 10 345 161 9 0 2 429 9 196 178 10 0 2 186 8 276 196 11 0 1 988 7 524 214 ...

Страница 14: ...ion Qty 1 7000967 Filter Cartridge 1 2 2180373 Filter Head 1 3 2190230 Adaptor 2 4 2170145 Flush Valve 1 5 Comes with head 2180373 Wall Bracket 1 6 Wall Bracket Side View 1 7 2180374 Standoff 1 8 2140188 Carbonate Hardness Test Kit 1 1 2 3 4 8 5 7 6 Components ...

Страница 15: ...HRS SERIES 15 P N 1011556 Rev A 08 19 Notes ...

Страница 16: ...ustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment DO N...

Отзывы: