Contents

Introduction 2

Before Use 

2

In Case of Damage 

2

Service/Technical Assistance 

2

Safety Information 

3

Installation 3

Operation 3

Maintenance 3

Service 3

Safety Information (Continued) 

3

Specifications 

4

Performance Data Sheet 

5

Filter Cartridge Capacities 

5

Performance Claims 

5

Overview 6

Construction 6

Unpacking 7

Equipment Setup 

7

Plumbing 7

Inlet Water Plumbing 

7

Installation Tools and Supplies 

7

Installation 8

Mounting the System 

8

Installation (Cont.) 

9

Filter Capacity and Blend Setting 

9

Sanitizing the System and Lines 

10

Replacing and Rinsing the Cartridge  10

Maintenance 11

Troubleshooting Chart 

11

Blend Setting Tables 

12

Blend Setting Tables 

13

Components 

14

Notes 

15

Limited Warranty 

16

Introduction

The system is an innovative filtration 

system that uses an ion exchange 

resin for cabonate hardness as well as 

a carbon element to provide the latest 

innovation in filtration technology.

Before Use

This manual provides the safety, 

installation, and operating procedures 

for the water filtration system. All 

information contained in this manual 

should be read prior to installing and 

operating the system.  Your system is 

manufactured from the finest materials 

available and is assembled to strict 

quality standards. This system has 

been tested at the factory to ensure 

dependable trouble-free operation. 

In Case of Damage

If the unit arrives damaged, file a claim 

with the carrier immediately. Save 

all packing materials when filing a 

claim. Freight damage claims are the 

responsibility of the purchaser and are 

not covered under warranty.

Service/Technical 

Assistance

If there are any problems with the instal-

lation or operation of the unit, contact 

Antunes Technical Service at 1-877-392-

7854 (toll free).
Fill in this information and have it handy 

when calling for assistance. The se-

rial number is on the specification plate 

located on the unit.

IMPORTANT

Antunes reserves the right to change 

specifications and product design 

without notice. Such revisions DO 

NOT entitle the buyer to corresponding 

changes, improvements, additions or 

replacements for previously purchased 

equipment.

IMPORTANT

Keep these instructions for future 

reference. If the system changes  

ownership, be sure this manual 

accompanies the equipment. 

Purchased from:

Date of purchase:

Model number:

Serial number:

Manufacturing number: 

 

Suggested replacement period for 

the Cartridge is approximately 1 year 

(dependent on water quality).
 

For sales in the state of Iowa:
Seller:

Date:

Buyer:

Date: 

Содержание HRS-200

Страница 1: ...andard 42 for the reduction of Chlorine Taste and Odor Owner s Manual Original Instructions Manufacturing Numbers 9700562 www antunes com CAUTION Read all instructions before using the unit Original Instructions P N 1011556 Rev A 07 19 HARDNESS REDUCTION SYSTEM HRS 200 ...

Страница 2: ...g the system Your system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ensure dependable trouble free operation In Case of Damage If the unit arrives damaged file a claim with the carrier immediately Save all packing materials when filing a claim Freight damage claims are the responsibility of the purc...

Страница 3: ... maximum operating temperature is 86 F 30 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping Mechanical damage external breakage and or internal breakage of the filter can result if the system is dropped or bumped Handle with care at all times during transportation and installation Protect from organic solvents and conce...

Страница 4: ...4 185 mm 23 5 8 600 mm Weight Cartridge Dry 16 5 lb 7 5 kg Cartridge Wet 24 25 lb 11 0 kg Model Drain must accommodate flow up to 9700562 HRS 200 1 gpm Model Replacement Cartridge 9700562 HRS 200 7000967 Cartridge HRS 200 System Inlet System Outlet 3 8 OD Tube or 1 2 ID Hose 3 8 OD Tube or 1 2 ID Hose B C A Figure 1 Cartridge Dimensions ...

Страница 5: ...onditions actual performance may vary DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Performance Data Sheet Filter Cartridge Capacities Minimum Operating Pressure 29 psig 200 kPa Maximum Operating Pressure 11...

Страница 6: ...h activated carbon to reduce chlorine taste and odors Figure 2 Water then passes through the ion exchange resin reducing the carbonate hardness Depending on the filter head blend setting some of the water that enters the cartridge may bypass the ion exchange resin This bypass water passes through the activated carbon for taste and odor reducton before mixing with the carbonate hardness reduced wat...

Страница 7: ...nnect the system to the hot water line The system uses the following connections System Inlet 3 8 OD Tube or 1 2 ID Hose System Outlet 3 8 OD Tube or 1 2 ID Hose DO NOT over tighten the connections Use plastic fittings when connecting to the plastic connections of the system If soldered plumbing is used DO NOT apply heat to or near the filtration system Use union O Ring seal connections for ease o...

Страница 8: ...he Flush Valve to the valve outlet 6 Attach the Water Meter if available to the outlet of the Flush Valve finger tight only 7 Attach an adaptor to the outlet of the Water Meter if available finger tight only 8 Connect the inlet to the water supply It is recommended that an inlet shut off valve not provided be installed ahead of the filter system 9 Connect the outlet of the filter system to the wat...

Страница 9: ...ss Set the blend Figure 9 based on the determined carbonate hardness and referring to the appropriate use in the Tables on pages 12 and 13 There are four possible settings for the blend Figure 10 The blend can be changed easily by twisting the cap on top of the filter head Turn the cap either clockwise or counter clockwise until the mark on the head points to the blend number Allow the cap to snap...

Страница 10: ...sanitizer is present 7 Close the faucet or tap 8 Let the system stand without water flow for at least 15 minutes to allow the sanitizer to sanitize the plumbing 9 After 15 minutes without water flow open the faucet or tap and allow water to flow through the system until the presence of sanitizer is gone Open all other faucets or taps in line with the system to flush any remaining sanitizer from th...

Страница 11: ...hed completely Heater boiler are not enough protected against lime scale Wrong chosen blend setting filter capacity is reached passed Check the hardness blend setting and the filter capacity Water meter display flashing Gallon capacity has been exceeded Change filter cartridge reset meter Water meter display flashing low battery Battery needs replacing Replace battery in meter Drinking water is fo...

Страница 12: ...3 1 585 6 000 445 25 2 1 364 5 164 463 26 2 1 312 4 966 481 27 2 1 263 4 782 499 28 2 1 218 4 611 517 29 2 1 176 4 452 534 30 2 1 137 4 303 534 30 2 1 034 3 912 ppm CaCO3 Grains per US gallon GPG Blend setting Filter capacity HRS 200 US gallons Liters 71 4 3 7 926 30 000 89 5 3 6 341 24 000 107 6 3 5 284 20 000 125 7 3 4 529 17 143 143 8 3 3 963 15 000 161 9 3 3 523 13 333 178 10 3 3 170 12 000 19...

Страница 13: ... 3 793 445 25 1 962 3 641 463 26 1 925 3 501 481 27 1 891 3 371 499 28 1 859 3 251 517 29 1 829 3 139 534 30 1 802 3 034 534 30 1 729 2 758 ppm CaCO3 Grains per US gallon GPG Blend setting Filter capacity HRS 200 US gallons Liters 71 4 0 5 466 20 690 89 5 0 4 373 16 552 107 6 0 3 644 13 793 125 7 0 3 124 11 823 143 8 0 2 733 10 345 161 9 0 2 429 9 196 178 10 0 2 186 8 276 196 11 0 1 988 7 524 214 ...

Страница 14: ...ion Qty 1 7000967 Filter Cartridge 1 2 2180373 Filter Head 1 3 2190230 Adaptor 2 4 2170145 Flush Valve 1 5 Comes with head 2180373 Wall Bracket 1 6 Wall Bracket Side View 1 7 2180374 Standoff 1 8 2140188 Carbonate Hardness Test Kit 1 1 2 3 4 8 5 7 6 Components ...

Страница 15: ...HRS SERIES 15 P N 1011556 Rev A 08 19 Notes ...

Страница 16: ...ustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment DO N...