P/N 1011965 Rev A 08/22

10

NOTE:

 Installation shall comply and 

accord with AS/NZS3500.1

Inlet Water Plumbing

Filtered water from a base filtration system 

should be connected to the inlet of the RO 

System.
Connect Beverage hose (not supplied) to 

the outlet of the base filtration system.

Before connecting to the RO System 

inlet, the plumbing from the base filtration 

system must be flushed clear of all debris. 

Hold a bucket at the inlet water line and 

slowly open the base filtration water valve. 

Allow the plumbing to flush until all debris 

is removed.

System Inlet Connection

The System Inlet has a 3/8” OD tube 

connection at the Inlet (Figure 6). 

Filtered Water Product Outlet 

Connection

The System Permeate has a 1/4” OD tube 

connection 

(Figure 6)

. Use 1/4” OD tubing, 

or larger (not supplied) to connect between 

the product outlet and the downstream 

equipment.

A Tee fitting (not supplied) should be 

installed in the line from the system to 

connect to a tank (Figure 7).
It is recommended that a shut-off valve be 

installed in the line to the tank.

Install Pre-filters and RO 

Membrane

If not already installed, install the Pre-filters 

and RO Membrane. 

The white sediment prefilter must be 

installed in the 

left

 prefilter housing, 

closest to the water inlet.

The carbon prefilter must be installed 

in the 

right

 prefilter housing, after the 

sediment prefilter.

The RO membrane 

must

 be installed with 

the brine seal on the right, nearest to the 

RO membrane housing inlet. It should only 

be inserted into the RO housing from the 

right side.

1. 

Pull out the tube which is inserted 

into the RO housing’s inlet (Figure 

8a)

2. 

Using the supplied wrench, 

unscrew the RO housing end cap 

and insert the RO membrane into 

the housing. The RO membrane 

must be installed with the brine 

seal on the right side, nearest to 

the RO membrane housing inlet. 

It should only be inserted into the 

RO housing from the right side.

Figure 7. 

Recommended Tank Connection

Figure 8. Prefilter and RO Membrane Housings

Base Filter 

System

RO 

System

To store

Shut-off 

Valve

Tank

Figure 6. 

Inlet and Outlet Connections

Permeate Inlet

Drain

3. 

Reattach the RO membrane 

housing end cap.

4. 

Insert the tube that was removed in 

step 1 into the RO housing inlet.

Sediment 

Prefilter

Carbon 

Prefilter

RO Membrane 

Housing

RO Membrane 

Housing End 

Cap

Figure 11a

The system provides WaterMark certified 

DuCV & PRV with water inlet connection 

size GB1/2. Please check the thread type 

& size.

Содержание 9710161

Страница 1: ...rse Osmosis System Owner s Manual Models AQ RO 400 AQ RO 400 NT AQ RO 600 AQ RO 600 NT Manufacturing Numbers 9710161 9710162 9710163 9710164 www antunes com CAUTION Read all instructions before using the unit Original Instructions ...

Страница 2: ...Service at 1 877 392 7854 toll free Fill in the information in the next column and have it handy when calling for assis tance The serial number is on the specifi cation plate located on the system Purchased From Date of Purchase Model Number Serial Number Mfg Number Suggested replacement period for the RO Cartridge is 1 year IMPORTANT This equipment is to be installed to comply with the basic plum...

Страница 3: ...lt Protect from direct sunlight or other UV sources Avoid long term exposure to direct sunlight or other UV sources The RO should be stored in a dark location Protect from high temperatures or abrupt variation in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping ...

Страница 4: ... 400 NT Reverse Osmosis Cartridge Single Pack 7002303 AQ RO 600 AQ RO 600 NT Reverse Osmosis Cartridge Single Pack 7002304 Replacement Cartridges CAUTION When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit CAUTION To ensure proper installation wall anchors for unit must be rated for AT LEAST 60lbs 30 k...

Страница 5: ...ximum Operating Temperature 100 F 38 C 100 F 38 C pH Range 4 10 4 10 Maximum Total Dissolved Solids TDS 1 000 ppm 1 000 ppm Maximum Hardness 60 gpg 60 gpg Silt Density Index 5 5 Iron Hydrogen Sulfide or Manganese 0 0 Nominal Capacity 400 600 Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 70 psig Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 80 psig Performance ...

Страница 6: ...nued to be filtered but the system will not flush This will cause the RO membrane to plug prematurely and reduce the life of the RO System y Tank Full Mode When the tank is full no water runs out of the drain line CAUTION Stopping the drain flow can cause the Filter to plug prematurely and may reduce the life of the filter Consult the factory for more information Figure 1 System Components Figure ...

Страница 7: ...nstallation The following tools and supplies are sug gested to help with the installation y Screwdriver y Adjustable Wrenches y Drill with Bits y Level y Tape Measure y Pipe Dope or Thread Seal Tape y Two Gallon Bucket y Fresh Unscented Liquid Chlorine Bleach y Pipe Wrenches y Hose or pipe for drain line Mounting the System The RO System comes with a Mounting Bracket for the system When mounting t...

Страница 8: ...on the air inlet valve 3 Once the tank air charge is set replace the protective cap on the air valve Drain Connection The drain is for flushing particle buildup out of the system during operation Install a sufficient length of 3 8 OD tubing not supplied from the drain outlet on top of the RO system to the drain When connecting the drain hose pay at tention to the following guidelines y The drain l...

Страница 9: ... starts to calculate When the running time is activated on the RO membrane the RO membrane lifetime is based on the calendar time and running time which value is reached first Items Status Filters F1 Prefilter a 10 100 Life Always on b 0 10 Life Symbol Flickering c 0 Life Symbol Off Maintenance IL on Buzz 3 times min F2 Carbon F3 RO Membrane Status PROCESSING a Letter on flickering system flushing...

Страница 10: ...the Pre filters and RO Membrane The white sediment prefilter must be installed in the left prefilter housing closest to the water inlet The carbon prefilter must be installed in the right prefilter housing after the sediment prefilter The RO membrane must be installed with the brine seal on the right nearest to the RO membrane housing inlet It should only be inserted into the RO housing from the r...

Страница 11: ... and let water into the system 6 Plug the power cord into an outlet The pump will come on and air in the pre filters and RO membrane will come out Wait 5 10 minutes until all air has been removed 7 Adjust the brine control valve so that the pressure gauge is 80 psi Opening the brine control valve increases the brine flow rate and lowers the membrane pressure and product water flow rate 8 Continue ...

Страница 12: ...RO The system is now ready for use Maintenance Replacing the RO Cartridge NOTE Always install a new Carbon cartridge after replacing the RO Cartridge 1 Turn off water to the system by closing the feed water valve and unplug the system power cord from the outlet 2 Close the tank valve 3 Depressurize the system 4 Pull out the tube which is inserted into the RO housing s inlet 5 Using the supplied wr...

Страница 13: ...rd the date the cartridges where changed and the next change date Replacing the Sediment Prefilter Cartridge NOTE Always install a new Sediment Prefilter Cartridge when replacing the Carbon cartridge 1 Turn off the water to the system by closing the feed water valve 2 Close the tank valve 3 Open a valve on the line to the store to depressurize the system 4 Unscrew the bowl and remove the old sedim...

Страница 14: ...lies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection Source of compressed air manual bicycle tire pump or air compressor CAUTION Air pre charge should be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre Charge Do NOT adjust the tank air pre charge with the system under pressure CAUTION Be ...

Страница 15: ... cartridges Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace carbon cartridges Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken membrane in RO Cartridge Replace RO Cartridge Flush runs continuously Tank pressure switch stuck open Replace tank pressure switch W...

Страница 16: ...s Exploded View 73 32 32 1 43 51 72 62 21 21 13 24 19 24 13 21 41 41 61 4 23 56 21 57 56 37 18 13 36 13 37 18 46 45 53 53 35 40 54 16 22 48 52 14 16 13 17 27 25 16 13 2 49 63 6 20 31 50 29 30 15 16 26 55 60 21 59 19 20 13 25 40 54 55 38 38 78 74 ...

Страница 17: ...ESSURE GAUGE PANEL MOUNTED 1 36 2170212 BLEND VALVE 3 8 TUBE PANEL MOUNTED 1 37 2180495 FILTER BOWL 2 38 2180495 FILTER HEAD 2 39 2180495 FILTER O RING 2 40 2180772 MOUNTING CLIP RO HSG 2 41 2180779 HOUSING BOWL AND HEAD RO 1 42 2180823 GLUE BOX RO CONTROLLER 1 43 2180824 SUPPORT FRAME RO CONTROLLER 1 44 2180825 PLASTIC CLIP M4 x 6 3mm 4 45 2190251 ADAPTOR TUBE TO 1 2 NPT 1 46 2190252 ADAPTOR 1 2 ...

Страница 18: ...ure F Feed Pressure psig Product Flowrate ml min Drain Flowrate ml min Percent Recovery Product TDS ppm Feed TDS ppm Percent Rejection Date Date Date Changed Sediment Next Sediment Change Changed Carbon Next Carbon Change Changed RO Next RO Change ...

Страница 19: ...P N 1011965 Rev A 08 22 19 Notes ...

Страница 20: ...nance calibration or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations ...

Отзывы: