UFL-500 SERIES
12
P/N 1012043 Rev B 11/19
®
Sanitizing the System and Lines
The plumbing must be sanitized to eliminate possible
contamination that may have occurred during the installation
process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach,
unscented 5.25 % - 6 % sodium hypochlorite) or Kay-5 sanitizer
solution (Sodium Dichloro-s-Triazinetrione Dihydrate, 6%) or
equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz. packet
of Kay-5 powder in 2 oz. (60 ml) of clean warm water. This can
be done by removing 1 inch from the top of the Kay-5 packet and
adding the 2 oz. of warm water to the packet. Mix with a coffee
stirrer to dissolve. When added to the system, this will create a
60-100 ppm chlorine solution.
NOTE:
Follow the handling and safety instructions
supplied with the sanitizer.
NOTE:
Sanitizing kit is NOT supplied.
1.
Follow the steps in the
Rinsing the UltraFilter Cartridge
in
the Installation section of this manual.
2.
Turn off the water to the system.
3.
Open the faucet or tap closest downstream to the
system.
4.
Allow the system and plumbing to drain.
5.
Allow the water to drain out of the system.
6.
Pour the sanitizer into the water line supplying the system
using a cup or funnel. Be sure to wear protective gear and
be careful not to spill the sanitizer onto clothing or skin.
7.
Slowly turn on the water supply to the system.
8.
Allow water to flow through the system and out of the open
faucet or tap until the smell of sanitizer is present.
9.
Close the faucet or tap.
10.
Let the system stand without water flow for at least 15
minutes to allow the sanitizer to sanitize the pipes.
11.
After 15 minutes without water flow, open the faucet or tap.
12.
Allow water to flow through the system until the
presence of sanitizer is gone.
13.
Open all other faucets and taps in line with the system to
flush any remaining sanitizer from the plumbing.
14.
Close all faucets and taps.
Rinsing the UltraFilter Cartridge
The UltraFilter Cartridge comes pre-installed in the UFL
system. The UltraFilter Cartridge must be rinsed before the
system is used to remove any air and protective solution.
NOTE:
UltraFilter Cartridge must be rinsed to drain before
use. Rinsing to drain removes storage solution
and air. DO NOT rinse into carbon if present.
Carbon life and/or performance may be affected.
NOTE:
DO NOT consume water used during this process.
1.
Close the Inlet Ball Valve
2.
Direct water from the outlet to a drain.
3.
Open the Outlet Ball Valve (if installed).
4.
Slowly open the Inlet Ball Valve. Air and water will come
out.
5.
Press the
FLUSH
button. The Drain Valve will open and
air and water will come out of the drain line. Repeat six
times to ensure all air and storage solution are flushed out
of the UltraFilter Cartridge.
6.
Continue to allow water to run at full flow out of the Outlet
Ball Valve for at least 15 minutes.
7.
After 15 minutes, close the Outlet Ball Valve and allow
the system to sit for 15 minutes without any water flow to
release any trapped air from the UltraFilter Cartridge.
8.
Inspect the unit for any leaks, repairing as needed.
9.
After 15 minutes, open the Outlet Ball Valve and wait for
15 more minutes to flush out any remaining air.
10.
Close the Outlet Ball Valve.
11.
Press the
FLUSH
button to open the Drain Valve. Repeat
six times to ensure any remaining air is flushed out of the
system.
12.
Open the closest downstream tap or faucet.
13.
Slowly open the Outlet Ball Valve and allow water to run
through the system and out the faucet for five minutes.