14 

 
 

 

www.antiktech.com 

 

Enable: 

rescale the video resolution of the output 

manually 

Scale Vertical: 

set the resolution in vertical 

576 

Scale Horizontal: 

set the resolution in horizon

 

720 

Null Filter:

   

On:

 filter away the null packages 

Off:

 the service is stuffed with null packages 

Note Null packet is essential for DVB applications, 

don't remove them. 

Null Filter: On 

Encode Start out   

Encode Start :   

Enter=Yes: 

the settings will be applied to the selected 

encoder, and start it to encode. 

Exit=No: 

cancel the settings to the selected encoder, 

which will keep the previous status

 

 

 

 

 

 

 

 

 

 

 

Remux 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remux 

Program List 

Program List:

 select the programs to remux. Click on 

Enter  to  select,  double  click  to  cancel.  (The 

program(s) will be marked with an asterisk (*) once be 

selected) 

Encoder 1: 

select the SPTS from encoder 1

 

Encoder 2:

 select the SPTS from encoder 2

 

Encoder 3:

 select the SPTS from encoder 3

 

Encoder 4:

 select the SPTS from encoder 4 

Encoder 5: 

select the SPTS from encoder 5

 

Encoder 6:

 select the SPTS from encoder 6

 

Encoder 7:

 select the SPTS from encoder 7

 

Encoder 8:

 select the SPTS from encoder 8 

ASI  Input: 

select  the  program(s)  inputted  via  ASI 

input port.   

IP  Input: 

select  the  program(s)  inputted  via  IP  input 

port. (Note: this sub-menu is displayed only when the 

IP I/O is configured as full-duplex mode.) 

 

Bit Rate 

Output  Bit  Rate:

  key  in  the  bit  rate  of  the  newly 

generated MPTS, valid range from 100~216000 Kb/s 

Output Bit Rate: 

38015Kb/s 

Packet Size 

188 Byte / 204 Byte 

188 Byte 

TS ID 

TS ID:

 key in the TSID of the newly generated MPTS, 

valid range from 0 to 65535 decimal 

TS ID:00008 

Remove CA 

ON: 

remove the CA descriptors that are carried within 

the inputted TS over ASI or IP

 

OFF:

 keep the CA descriptors

 

OFF 

Содержание EX-5108

Страница 1: ...USER MANUAL EX 5108 8 Way H 264 HD SD Encoder...

Страница 2: ...TS IP Multiple Output mode EX 5108 08 08 6 Front panel and rear panel instructions 08 6 1 Front panel 09 6 2 Rear panel 10 7 Control with Front Panel 10 7 1 Overview of the Menu 10 7 2 Description of...

Страница 3: ...ARMONISED STANDARDS The CE mark which is attached to these products means it conforms to EMC Directive 89 336 EEC and Low Voltage Directive 73 23 EEC IMPORTANT INFORMATION Please retain the original p...

Страница 4: ...not stand the product on soft furnishings or carpets Do not stack electronic equipment on top of the product Do not place the product in a location subject to extreme changes in temperature The temper...

Страница 5: ...vice it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that s...

Страница 6: ...fed SPTS lower bit rate but less PCR accurate than normal SPTS from local encoders and 1 MPTS from internal reMultiplexer over the IP with different Unicast or Multicast IP addresses EX 5108 allows us...

Страница 7: ...downscale at same frame rate Aspect Ratio 4 3 16 9 Selectable Audio Input compression Input HDMI or SDI Embedded audio Audio Compression MPEG1 Layer II MPEG2 AAC LC MPEG4 AAC LC option for EX 5108 Sam...

Страница 8: ...8 ASI Out 2 BNC Female 75 1 Backup Front Panel Control 1 RJ 45 10 100 Base T TS IP 1 IP GbE RJ 45 10 100 1000 Base T Display 2 x 20 LCD Display Others Power Supply AC90 260V 50 60Hz Operating Temperat...

Страница 9: ...7 www antiktech com 5 Block Diagram with different applications 5 1 TS IP Full Duplex mode EX 5108 H S...

Страница 10: ...mode EX 5108 H S 6 Front panel and rear panel instructions 6 1 Front panel A1 Status LEDs Power green when power is on red when one of the power supply unit malfunction Warning red when function faul...

Страница 11: ...lid A3 VFD Panel A4 Keypad 6 keys for local control A5 USB Used to upgrade software version of this device A6 Management Ethernet 10 100 LAN control port A7 TS IP TS over IP I O port 6 2 Rear panel of...

Страница 12: ...u 1 Status show the status of the device 2 Configuration Configure and monitor parameters of encoding transcoding 3 System Configure the local settings of the device 7 2 Description of menu The main m...

Страница 13: ...ideo 3 Input Format Display the video format of input port 3 Video 4 Input Format Display the video format of input port 4 Video 5 Input Format Display the video format of input port 5 Video 6 Input F...

Страница 14: ...er 6 is active for configuration Encoder 7 the encoder 7 is active for configuration Encoder 8 the encoder 8 is active for configuration Video Settings Video Rate Ctl CBR set constant bit rate mode VB...

Страница 15: ...128 Kbps Audio Channel Mode Stereo Audio1 Level 0dB Audio SDI EMB EMB1 Encoder Bit Rate Encoder Bit Rate 600 48000Kbps set the output bit rate of the selected encoder Note Encoder bit rate must great...

Страница 16: ...ed Encoder 1 select the SPTS from encoder 1 Encoder 2 select the SPTS from encoder 2 Encoder 3 select the SPTS from encoder 3 Encoder 4 select the SPTS from encoder 4 Encoder 5 select the SPTS from en...

Страница 17: ...ber valid range from 1 65535 Target MAC Address set the destination port number MAC Address Gigabit Out Switch ON OFF to switch on off the current channel MUX ASI Out set the source for IP output chan...

Страница 18: ...estination port number valid range from 1 65535 Uni Multi UDP Port 01234 ProMPEG FEC Switch Enable Disable ProMPEG FEC Switch Disable ProMPEG FEC Mode 1D 5x5 1D 5x20 1D 10x10 2D 5x5 2D 5x20 2D 10x10 P...

Страница 19: ...ess set the IP address of the SNMP Trap server valid range from 0 0 0 0 255 255 255 255 Trap IP Address 10 10 70 25 Device Label Device Label user allows to rename the device press Enter and key in th...

Страница 20: ...h Web Server EX 5108 has an integrated web server This web server allows the configuration and status requests with a standard web browser To operate a EX 5108 first make sure the Ethernet control por...

Страница 21: ...antiktech com Input Status Input Video Format 8 2 Encoder There are eight encoders integrated on one EX 5108 each encoder can work independently Click on the to configure the encoder 1 the same for th...

Страница 22: ...embedded audio from input SDI signal the menu is displayed on EX 5108 S only Encoder Bit Rate set the output bit rate of the current encoder Encoder bit rate must greater than the sum of video bit ra...

Страница 23: ...Multiple output which delivers up to five streams over IP There are four stuffed or un stuffed SPTS and one MPTS from internal reMultiplexer over the IP with different Unicast or Multicast IP addresse...

Страница 24: ...please refer to chapter 8 5 System Device Gigabit Input Under Multiple output mode the Gigabit Input is not available Local Settings Set the parameters for the TS IP output port Gigabit Address set t...

Страница 25: ...k Recover Auto it is suggested to set Auto when there is accurate PCR carried by the inputted TS IP Fixed Rate when fixed rate is selected user has to configure a bit rate to regenerate the TS clock T...

Страница 26: ...IP streaming Uni Multi IP Address set the unicast or multicast IP address for the output IP streaming Uni Multi UDP Port set the port number valid range from 1 65535 ProMPEG FEC Switch Enable or Disab...

Страница 27: ...the IP port is connected Gateway MAC Address set the MAC address of the gateway under which the device is connected this is necessary when the IP streaming is needed to pass through the gateways 8 4 M...

Страница 28: ...total bitrate of selected programs otherwise packets may dropout TS ID Set the TSID of the new generated transport stream valid range from 0 to 65535 decimal Insert EIT ON insert EIT into the output s...

Страница 29: ...d the serial number of this device User can resign this product name at will the device name should be less than 24 characters The serial number is read only Serial Number show the serial number for t...

Страница 30: ...be modified by user Version User can check versions of various functional blocks of the device as it shown in figure below Login Set the login ID and password for the web management server of the dev...

Страница 31: ...n EIA standard 19 rack any other mounting method may lead to damage to the device Open the box and take out the device with care Inspect if there is any damage to the appearance of the device Fix the...

Страница 32: ...or LED A4 should be green and always light on during working The EX 5108 needs 1 5 2 minutes to boot up completely Configure the network settings of the device via front panel Make the settings of Enc...

Страница 33: ...ANTIK Technology www antiktech com juicesales antiktech com support antiktech com...

Отзывы: