TROUBLESHOOTING GUIDE

Is the table giving you trouble?  Try these steps first.  Still need help?  Contact Anthro at 800.325.3841.  

Table won't go up, but it will go down.  

 

ƒ

Inspect the leg cables, control box cable, and power cable to be sure they are connected properly and not damaged.  Need 

replacements?  Contact Anthro at 800.325.3841.

 

ƒ

Lower the table to its lowest position, release the button, the press the DOWN button again for 5 seconds to home the 

legs.  The table will bump a few times, then rest.

Table won't move at all: no up, no down.

 

ƒ

Has the table exceeded its duty cycle, moving more than 6 minutes per hour or 2 minutes continuously?  If so, rest the 

table for 20 minutes and try again.  

 

ƒ

Inspect the leg cables, control box cable, and power cable to be sure they are connected properly and not damaged.  

 

ƒ

Test the cables:

 

• Unplug the Leg Cable that is plugged into Port 1 of the control box.

 

• Push the DOWN button for 3 seconds and then the UP button for 3 seconds.

 

• Unplug the Power Cord from the Control Box.

 

• Plug the Leg Cable back into Port 1.

 

• Plug the Power Cord back into the Control Box.

 

• Push the DOWN button and hold until the table reaches its lowest position and stops, then release.

 

• Push the DOWN button again and hold for 5 seconds.

 

• Push the UP button to verify the that the table goes up.

Desk will only go up a few inches...then stop...then up another few inches...then stop again.  

 

ƒ

Verify that the load on the table does not exceed its 150 lbs lift capacity.  

Cleaning instructions?  

Clean the table with a mild detergent and a soft cloth. 

*300-5582-00*

300-5582-00

SAFETY CHECK

 

ƒ

Plug in the table and home the legs.  To home the legs, move the table to its lowest position, release the DOWN button, 

then press and hold the DOWN button for 5 seconds.  The table will bump a few times, then rest.

 

ƒ

Raise the table to its highest position.  Watch all the cords and cables as the table moves to verify that cords aren't 

wrapped around anything and that nothing interferes with the movement of the table.

 

ƒ

Every time you add equipment onto the table, route cords into the cable tray.  Carefully move the table through its entire 

range of motion to be sure that your power and data cables are long enough.  Check the area around your table for 

obstructions below, beside, and above the table to be sure there are no collisions.  

 

ƒ

Verify that the load is distributed evenly across the table. 

MOVING THE TABLE

 

ƒ

Keep your equipment safe: remove equipment from the table before you move it.

 

ƒ

Before moving the table, lower the table all the way down and raise the keyboard surface all the way up.  

 

ƒ

To move the table, lift the front keyboard surface enough to get the front feet off the ground, and roll it into place.

 

ƒ

Lift (don't roll) the table over thresholds, transitions, or bumps.  

Содержание Elevate II Adjusta

Страница 1: ...3 691 2556 Fax 503 691 2409 Rev G February 2016 NOTE The CPU SideRack Inboard is not included Part Product MVJB48zz xx ELT 2 Adjusta 48w MVJB60zz xx ELT 2 Adjusta 60w Certification Elevate II Adjusta is certified by ETL to UL962 standard for Commercial and Household furnishings ASSEMBLY INSTRUCTIONS Elevate II Adjusta Dual surface Table ...

Страница 2: ...important de respecter certaines précautions de base notamment celles décrites ci dessous Lire intégralement les consignes avant d utiliser ce mobilier DANGER Pour limiter le risque de choc électrique toujours débrancher le mobilier avant de nettoyer AVERTISSEMENT Pour limiter les risques de brûlure d incendie de choc électrique ou de blessure aux personnes 1 Débrancher avant d installer ou de ret...

Страница 3: ...er 1 400 5358 00 14 Foot 2 835 5581 00 15 Adjusta Mechanism 1 for 48w Table 225 5546 00 for 60w Table 575 5072 00 Product Quantity Part Number 16 1 2 Button head Screw 7 325 5193 00 17 Nylock Nut 7 325 5186 00 18 M6 20 Cap Screw 8 325 5272 00 19 3 4 Phillips Screw 4 325 5370 00 20 3 4 Button head Screw 56 325 5575 00 21 M6x14 Flat head Screw 4 325 5435 00 22 M6 10 Button head Screw 8 325 5503 00 2...

Страница 4: ...et so the cord feeds out of the Leg toward the center of the table The Leg will rest on top of the Gusset s button head screws so it may feel a little wobbly A Slide a Leg Housing over the Leg and down until it covers the Leg Motor and the six screw holes on the housing line up with the six pre drilled holes on the shelf B Move to the front of the table and attach the front of the Housing to the L...

Страница 5: ...rovided and the smallest hex key 1 8 in your kit 1 2 Button hd Screw 325 5193 00 Nylock Nuts 325 5186 00 Attaching the Control Box to the Cable Tray of a shallow 48 wide table 1 2 Flat head Screw 325 5193 00 Nylock Nuts 325 5186 00 M6 10 Button head Screw 325 5503 00 3 4 Button Hd PB Screw 325 5575 00 STEP 5 INSTALL CABLE TRAY Align the Cable Tray with the back of the table so the holes on the thr...

Страница 6: ...sing a total of six 3 4 Button head Screws Align the brake assembly with the six holes on the Monitor Surface It may be necessary to depress the paddle in order to position the brake Secure the brake assembly with six 3 4 Button head Screws Mechanism Arm Mechanism Arm 3 4 Button Hd PB Screw 325 5575 00 Cotter Pin included with 225 5548 00 Cotter Pin Post Center Crossbar Flanges Brake Shaft Crossba...

Страница 7: ...ns are face down at the front edge of the keyboard surface and the flat side of the housing is against the shelf Using four Phillips Head Screws attach the keypad and its housing to the front of the worksurface Route the Keypad s cable back to the Cross Pan and plug it into the Control Box Feed extra cable length through an opening in the support pan so it s organized in the Cable Tray 3 4 Phillip...

Страница 8: ...h the DOWN button and hold until the table reaches its lowest position and stops then release Push the DOWN button again and hold for 5 seconds Push the UP button to verify the that the table goes up Desk will only go up a few inches then stop then up another few inches then stop again Verify that the load on the table does not exceed its 150 lbs lift capacity Cleaning instructions Clean the table...

Отзывы: