background image

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should always be followed, including the following.  

Read all instructions before using Elevate II Adjusta.

DANGER

To reduce the risk of electric shock, always unplug this furnishing from the electrical outlet  

before cleaning.

WARNING

To reduce the risk of burns, fire, electric shock, or injury to persons:

1.  Unplug from outlet before putting on or taking of parts.
2.  Close supervision is necessary when this furnishing is used by or near children, invalids, or disabled persons.
3.  Use this furnishing only for its intended use as a described in these instructions.  Do not use attachments not  

recommended by the manufacturer.

4.  Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or 

dropped into water.  Any damage to the electrical system must be examined 

&

 repaired by a qualified electrician.

5.  Keep the cord away from heated surfaces.
6.  Do not use outdoors.
7.  Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8.  To disconnect, remove plug from outlet.
9.  The control box and legs have no user-serviceable parts and must be replaced by components from Anthro.
10. Power cord moves up and down with the table.  Make sure power cord moves freely through all positions  

of the desk.

11. Protect the power cord from damage when moving the desk.
12. Maximum load is 150 lbs.

SAVE THESE INSTRUCTIONS

CONSIGNES DE SÉCURITÉ IMPORTANTES

En cas d’utilisation de mobilier alimenté électriquement, il est important de respecter certaines précautions 

de base, notamment celles décrites ci-dessous. Lire intégralement les consignes avant d'utiliser ce mobilier.

DANGER 

Pour limiter le risque de choc électrique, toujours débrancher le mobilier avant de nettoyer.

AVERTISSEMENT 

Pour limiter les risques de brûlure, d’incendie, de choc électrique ou de blessure aux personnes :

1.  Débrancher avant d'installer ou de retirer des pièces.
2.  Une surveillance étroite est nécessaire lorsque ce mobilier est utilisé par ou à proximité des enfants, des personnes invalides ou 

handicapées.

3.  Utiliser ce mobilier uniquement pour l’usage auquel il est destiné, tel que détaillé dans ces consignes. Ne pas utiliser d’accessoires non 

recommandés par le fabricant.

4.  Ne jamais utiliser ce mobilier si un cordon ou une prise électrique est endommagé, ou s’il ne fonctionne pas correctement, s’il a 

été échappé ou endommagé ou s’il est tombé dans l'eau. Tout dispositif électrique endommagé doit être évalué et réparé par un 

électricien qualifié.

5.  Maintenir le cordon électrique à l’écart de toute source de chaleur.
6.  Ne pas utiliser à l’extérieur.
7.  Ne pas utiliser où des produits aérosols (pulvérisateurs) sont utilisés ou lorsque de l’oxygène est administré.
8.  Mettre le mobilier hors tension en débranchant de la prise.
9.  Le boîtier de commande et les pieds ne comportent aucun élément réparable par l’utilisateur et doivent être exclusivement remplacés 

par des composants Anthro.

10. Le cordon d'alimentation monte et descend avec la table. Veuillez vous assurer que le cordon d'alimentation soit libre de se déplacer 

quelle que soit la position du bureau.

11. Protéger le cordon d'alimentation contre tout dommage lors du changement de position du bureau.
12. La charge maximale est de 68 kg. 

CONSERVEZ CES CONSIGNES

Содержание Elevate II Adjusta

Страница 1: ...3 691 2556 Fax 503 691 2409 Rev G February 2016 NOTE The CPU SideRack Inboard is not included Part Product MVJB48zz xx ELT 2 Adjusta 48w MVJB60zz xx ELT 2 Adjusta 60w Certification Elevate II Adjusta is certified by ETL to UL962 standard for Commercial and Household furnishings ASSEMBLY INSTRUCTIONS Elevate II Adjusta Dual surface Table ...

Страница 2: ...important de respecter certaines précautions de base notamment celles décrites ci dessous Lire intégralement les consignes avant d utiliser ce mobilier DANGER Pour limiter le risque de choc électrique toujours débrancher le mobilier avant de nettoyer AVERTISSEMENT Pour limiter les risques de brûlure d incendie de choc électrique ou de blessure aux personnes 1 Débrancher avant d installer ou de ret...

Страница 3: ...er 1 400 5358 00 14 Foot 2 835 5581 00 15 Adjusta Mechanism 1 for 48w Table 225 5546 00 for 60w Table 575 5072 00 Product Quantity Part Number 16 1 2 Button head Screw 7 325 5193 00 17 Nylock Nut 7 325 5186 00 18 M6 20 Cap Screw 8 325 5272 00 19 3 4 Phillips Screw 4 325 5370 00 20 3 4 Button head Screw 56 325 5575 00 21 M6x14 Flat head Screw 4 325 5435 00 22 M6 10 Button head Screw 8 325 5503 00 2...

Страница 4: ...et so the cord feeds out of the Leg toward the center of the table The Leg will rest on top of the Gusset s button head screws so it may feel a little wobbly A Slide a Leg Housing over the Leg and down until it covers the Leg Motor and the six screw holes on the housing line up with the six pre drilled holes on the shelf B Move to the front of the table and attach the front of the Housing to the L...

Страница 5: ...rovided and the smallest hex key 1 8 in your kit 1 2 Button hd Screw 325 5193 00 Nylock Nuts 325 5186 00 Attaching the Control Box to the Cable Tray of a shallow 48 wide table 1 2 Flat head Screw 325 5193 00 Nylock Nuts 325 5186 00 M6 10 Button head Screw 325 5503 00 3 4 Button Hd PB Screw 325 5575 00 STEP 5 INSTALL CABLE TRAY Align the Cable Tray with the back of the table so the holes on the thr...

Страница 6: ...sing a total of six 3 4 Button head Screws Align the brake assembly with the six holes on the Monitor Surface It may be necessary to depress the paddle in order to position the brake Secure the brake assembly with six 3 4 Button head Screws Mechanism Arm Mechanism Arm 3 4 Button Hd PB Screw 325 5575 00 Cotter Pin included with 225 5548 00 Cotter Pin Post Center Crossbar Flanges Brake Shaft Crossba...

Страница 7: ...ns are face down at the front edge of the keyboard surface and the flat side of the housing is against the shelf Using four Phillips Head Screws attach the keypad and its housing to the front of the worksurface Route the Keypad s cable back to the Cross Pan and plug it into the Control Box Feed extra cable length through an opening in the support pan so it s organized in the Cable Tray 3 4 Phillip...

Страница 8: ...h the DOWN button and hold until the table reaches its lowest position and stops then release Push the DOWN button again and hold for 5 seconds Push the UP button to verify the that the table goes up Desk will only go up a few inches then stop then up another few inches then stop again Verify that the load on the table does not exceed its 150 lbs lift capacity Cleaning instructions Clean the table...

Отзывы: