background image

MTU-GLR Maintenance 

 

Anthony Liftgates, Inc. 

800-482-0003 

 www.anthonyliftgates.com

1.5  Registration

Refer to the Operation Manual for the serial number 

information.

1.6  Warranty

For a detailed copy of the Warranty Statement, refer to 

the Operation Manual. To make an online warranty claim, 

go to www.anthonyliftgates.com and select CUSTOMER 

SERVICE and then select WARRANTY CLAIM.

ALI-00418

Before calling with questions or other product information 

requests, have the serial number, model number, and 

lift capacity of the liftgate available. This information is 

stamped into the identification plate on the side of the 

adapter frame tube.

NOTICE

The liftgate must be maintained 

according to these instructions or 

the warranty will be void.

1.  Unauthorized modifications may cause improper 

operation or other unforeseen problems or dangers.  

If any deviation is deemed necessary, written 

permission must be obtained from Anthony Liftgates.

2.  All decals must be attached and legible, or all 

warranties are void.

2.  Safety

2.1  Safety is Your Responsibility

It is the responsibility of the maintenance personnel to 

understand proper operating procedures. Be aware of the 

inherent dangers in the use of this product and the tools 

used to maintain it. Read and understand all Warnings, 

Cautions, Notices, Safety Instructions, and Notes in this 

manual, on the liftgate, or on the truck.
Accidents can often be avoided by being alert and 

recognizing potentially hazardous situations. The safety 

information in this manual serves as a basic guide in an 

attempt to prevent injury or death.
Anthony Liftgates cannot anticipate every possible 

circumstance that might involve a potential hazard. The 

warnings in this manual and on the product itself are, 

therefore, not all-inclusive. If tools, procedures, work 

methods, or operating techniques are used that are not 

specifically mentioned by Anthony Liftgates, you must 

satisfy yourself that they are safe for you and for others. 
DO NOT proceed with any maintenance procedure 

if doubt arises about the correct or safe method of 

performing any procedure found in this manual. If you 

have any doubts or questions about installation, call your 

authorized dealer. 

Safety Signal Words

Personal injury hazards are identified by the 

“Safety Alert Symbol” and followed by a signal 

word such as WARNING or CAUTION to indicate 

the severity of the hazard.

This safety alert icon surrounds an image showing 

a specific type of injury which should be avoided. 

These icons are shown in “2.2.3 Hazard 

Avoidance” on page 6.

WARNING

 Indicates a potentially hazardous 

situation which, if not avoided, 

COULD result in death or serious 

injury.

CAUTION

 Indicates a potentially hazardous 

situation which, if not avoided, 

MAY result in minor or moderate 

injury. 

NOTICE

Indicates that equipment or property 

damage can result if instructions 

are not followed. 

 

SAFETY

 INSTRUCTIONS

 Indicates specific safety-related 

instructions or procedures. 

 

Note:

  

Contains additional information important to a 

procedure.

Содержание MTU-GLR Series

Страница 1: ...Made in the USA MTU GLR MTU GLR WR 3 MTU GLR WR 4 MTU GLR EX 3 MTU GLR EX 4 MTU GLR 25 MTU GLR 3 MTU GLR 4 MTU GLR 5 MTU GLR 6 Quality Reliability Customer Service MTU GLR 3 4 Shown MAINTENANCE MANUAL...

Страница 2: ......

Страница 3: ...4 2 Semi Annual Inspection 10 4 3 Adjusting Wheel Arm 10 4 4 Platform Adjustment 11 4 5 Replace the Power Cable Fuse 12 4 5 1 Replace the 200 AMP Fuse 12 4 5 2 Replace the 175 AMP Fuse 12 4 6 Checkin...

Страница 4: ...ng is installed or changed it must not alter or prevent vehicle compliance with any existing State or Federal standards such as FMVSS 108 Lamps Reflective Devices and Associated Equipment 1 3 2 Rear I...

Страница 5: ...ded by being alert and recognizing potentially hazardous situations The safety information in this manual serves as a basic guide in an attempt to prevent injury or death Anthony Liftgates cannot anti...

Страница 6: ...ed Actions Do not alter or modify Do not weld No smoking No open flame No alcohol No drugs 2 2 3 Hazard Avoidance Safety alert symbol Slipping injury Tripping injury Pinch point hazard Pinch hazard fo...

Страница 7: ...e damaged A cut battery cable can cause sparks and or component damage resulting in loss of vehicle control serious injury or even death CAUTION OEM If replacement parts are necessary genuine factory...

Страница 8: ...ess There are no long term health effects Metal fume fever typically begins about four hours after exposure and full recovery occurs within 48 hours 2 4 2 Stainless Steel Follow all OSHA and other wor...

Страница 9: ...Port and Breather Cap Reservoir Power Up High Pressure Hose Flow Control Valve Power Down High Pressure Hose Motor Start Solenoid Pump Adjustable Relief Valves Control Box Wiring 10 Amp In Line Fuse...

Страница 10: ...ot mix hydraulic oil and automatic transmission fluid due to possible compatibility problems Use the appropriate viscosity of fluid based on the surrounding climate conditions Viscosity is important b...

Страница 11: ...4 ALI 00590 1 The platform should lower parallel to the ground until the back portion nearest the truck touches It should then tilt forward until the front edge touches the ground 1 2 ALI 00589 2 To r...

Страница 12: ...a is clear 4 5 2 Replace the 175 AMP Fuse CAUTION To avoid injury or property damage disconnect the liftgate s power cable from the battery before starting to replace the fuse An arc can occur resulti...

Страница 13: ...Checking Lowering Valve Cartridge and Solenoid 1 Place the liftgate on the ground in the open position 2 Place a steel screwdriver over the top of the lowering valve solenoid ALI 00593 3 Momentarily...

Страница 14: ...o the power up port 3 Connect a pressure gauge and reconnect the hydraulic hose The pressure gauge must be rated above the maximum pressure of the liftgate For example use a 4000 psi pressure gauge on...

Страница 15: ...eservoir In an emergency use any anti wear hydraulic fluid but flush the system and replace it with our recommended fluid soon as reasonably possible Do not mix hydraulic oil and automatic transmissio...

Страница 16: ...is control circuit If blown pull fuse holder cap replace fuse replace cap If fuse continue s to blow contact a qualified mechan ic control circuit may be damage d FUSIBL E DE 10 AMPER IOS Y SOPOR TE P...

Страница 17: ...d and store platform Make sure platform is locked in storage position with latch pin after use 6 Manually unfold main platform Always stand on curbside of truck when unfolding platform 3 Manually unfo...

Страница 18: ...otects against dead shorts in this control circuit If blown pull fuse holder cap replace fuse replace cap If fuse continues to blow contact a qualified mechanic control circuit may be damaged 12 A 131...

Страница 19: ...hexavalent chromium fumes that can irritate the nose throat and lungs Repeated or prolonged exposure can damage the mucous membranes of the nasal passages and result in ulcers In severe cases exposure...

Страница 20: ...e Connect motor directly to a spare battery using the procedure in the Maintenance section Motor If the motor is determined to be defective it should be replaced Defective motors are typically caused...

Страница 21: ...maged parts Low fluid level Fill reservoir 4 1 Monthly Inspection on page 10 Low Voltage Inspect the battery connection terminals and check the battery s Voltage 9 Volts minimum Faulty lowering valve...

Страница 22: ...der operates properly replace the valve 4 13 Checking Flow Control Valve on page 14 Lowering valve Solenoid or cartridge may need cleaning or replacement See Maintenance section 4 8 Checking Lowering...

Страница 23: ...NOTES...

Страница 24: ...5 PH 815 842 3383 FAX 815 844 3612 TOLL FREE 800 482 0003 WWW ANTHONYLIFTGATES COM THE ORIGINAL NAME IN LIFTGATES SINCE 1941 Gentle Level Ride GLR Our platform maintains a smooth level up and down ope...

Отзывы: