4.14 Checking Control Switch Fuse
If the control switch is not operating the liftgate, check the
in-line fuse located on the control cable inside the power
unit box.
ALI-00596
ALI-00597
4.15 Power Module Fluid
Power down models - With the platform fully raised,
the oil level should be within 2 inches of the top of the
reservoir.
2”
ALI-00613a
NOTICE
To prevent damage to the pump,
use only the recommended Hyken
Glacial Blu anti-wear, low-viscosity,
hydraulic fluid in the power unit reservoir.
In an emergency, use any anti-wear hydraulic fluid, but
flush the system and replace it with our recommended
fluid soon as reasonably possible. Do not mix hydraulic
oil and automatic transmission fluid due to possible
compatibility problems.
Use the appropriate viscosity of fluid based on the
surrounding climate conditions. Viscosity is important
because the pump will not cause a temperature increase
to the oil in the reservoir, like a typical closed-loop
hydraulic system.
DO NOT use brake fluid in place of our recommended
fluids.
4.16 Reattach Control Unit Wires to Appropriate
Terminals
Black wire
Yellow solenoid
wire to green
control switch
wire
Yellow solenoid
wire to red control
switch wire
White wire to
motor start
solenoid
ALI-00
598
Power Down