Q:  What if I left the scanner connected for a long time after upload? 

 

Close the PI, and Anthology.  You may also need to shut down the computer for 1 minute and 
change the batteries as well if left for an extended period of time.   

 

Q:  After shutting down the program, checking the cable connections, I still get an error saying I cannot 
download the data from the scanner.  I have tried repeatedly with different scanners and am unable to 
download any scanners. 

 

First, stop all scanning.  Close out of Anthology, disconnect the scanner from the cable, and shut 
down the PI machine for 5 full minutes.  Bring the system back up and do a Quickbackup, and a 
Reindex from the tools menu.  Pick one scanner and empty it by holding the (-) for 20 seconds 
until it beeps.  Scan only 2-3 items as a test.  Do not attempt to download other scanners at this 
time, concentrate only on this one scanner and getting the communications functioning again.  Go 
to the Master PI record and hold the scanner and cable in one hand, but not connected.  Go to 
the Action menu and choose “Get Data From Scanner”.  Then immediately connect the scanner 
to the cable.  Remember, that these scanners want to send the data as soon as they are 
connected.  Think of the connection process as opening the door (Get Data) and walking through 
the door (connecting the cable).  If you still experience problems you may need to replace the 
batteries on the scanner, or shut down the PI machine, disconnect the cables, and try to connect 
the PI scanner cable to a different machine.  In rare cases the cable could be damaged, you 
should have received a backup cable to try.  Know that the USB driver will need to be reinstalled 
if the scanner cable is moved to a different USB port or different computer. 

 

Q:  What if I followed all the troubleshooting tips and I still can not upload? 

 

Shut down computers and move the cable connection to another computer. 

 

As an absolute last resort, if after following the above directions you still have problems 
downloading batches, stores on support may page.  Please be aware that techs are instructed to 
offer only 5-10 minutes assistance, but we cannot guaranty the issue can be resolved on an 
emergency page basis.  Some problems may only be resolved by a login M-F, 9-5pm eastern. 

 

Please be aware that if you page, the tech on call will ask you to go through the same 
troubleshooting procedures listed here.  When the scanner malfunctions, there is very little a tech 
can do 

remotely

 

Q:  What if I have problems posting a batch after hours? 

 

Note the problem batch number, do not post it.  Continue with other scanning but do not complete 
the PI.  You can safely hold off on completing the PI even if the store must open and do sales the 
next day.  Email 

[email protected]

 with the information and a tech will contact you the 

next business day.

 

 

Please be aware that if you page, the tech on call will ask you to go through the same 
troubleshooting procedures listed here. 

Содержание CS1504 Series

Страница 1: ...y be using Visual Anthology version 5 16 058 or higher to use the PI module and these scanners NOTE You will need to purchase batteries to be used with the scanners While we may provide one set to get you started you will need more Symbol recommends using 4 Energizer EPX76 batteries in each scanner for optimal performance They further state that a brand new set of 4 batteries per scanner will do r...

Страница 2: ...e disconnect the device then power the station back on This should allow the computer to recognize the device is no longer connected 2 Verify the USB adaptor is firmly attached to the Serial connector The male and female serial connectors can be screwed together for stability 3 Plug the USB end into the computer and allow a few moments for the computer to recognize new hardware You may receive a m...

Страница 3: ...ing of numbers and letters that is case sensitive 7 Save settings This authorization code will allow you to use the rental scanners for a set number of days A message will display indicating how long the scanners can be used 8 Repeat these same steps with your Test Copy if you ve created one to practice with before the real PI Doing the PI You should use the information found in the PI Physical In...

Страница 4: ...qty s added to the CountQty in the master PI Doing an F12 Post Update in the master PI will add the CountQty values to the TotalCount column and will create a batch record with the status of Manual as an audit trail for you later 13 Every few hours save your work and close out of the PI Go to the Tools menu and run a quickbackup then Reindex This will give you restore points in case of a serious p...

Страница 5: ...an you can delete the last scanned item Press the small button marked with a and rescan the item A beep will sound and the scanner will flash yellow Be sure to scan the correct barcode Many books have two different barcodes printed on them The correct one to scan for books is called an EAN13 barcode which starts with 978 Please read the help system section entitled Special Topics Understanding Bar...

Страница 6: ...ide up and the two batteries on the right should be printed side down Putting in the batteries incorrectly could seriously damage the scanner Q How long do the batteries last Symbol estimates up to 5 000 scans on a fresh set of batteries Q How do I know the collector is full or the batteries are low The scanner will emit a beep when it is getting full and another when it is full A different signal...

Страница 7: ...in the scanner and chose the Get Data From Scanner option from the Action menu and am getting this error message How can I get my scanner to download again Unplug the scanner click ok close out of the PI and Anthology Open Anthology and the PI back up It s critical that you connect the scanner first and then do the Get command not the other way around Q I get the following error when trying to dow...

Страница 8: ... will be accepted You can simply create a new PI with the missed section only Do not create a new partial PI that has a section already selected in a previous PI created during this physical inventory Q I included a section on the PI but that section of items was missed in the scanning What happened to the Inventory OH s when the PI was posted If you have missed a physical section yet had the sect...

Страница 9: ...necting the cable If you still experience problems you may need to replace the batteries on the scanner or shut down the PI machine disconnect the cables and try to connect the PI scanner cable to a different machine In rare cases the cable could be damaged you should have received a backup cable to try Know that the USB driver will need to be reinstalled if the scanner cable is moved to a differe...

Отзывы: