For transmitters for which the rated maximum output power has not been given above, the recommended separation distance "d" in me-
tres (m) can be estimated by using the equation applicable to the transmitter frequency, where 'P' is the characteristic of maximum trans-
mission power of the transmitter in watts (W), according to the manufacturer.  

NOTE 1 : U

T

 is the AC voltage of the network before application of the test level.  

NOTE 2 : At 80 MHz and at 800 MHz, the higher frequency range applies.  
NOTE 3 : These directives may not apply in all situations. Electromagnetic propagation is affected by the absorption and the  reflection by structures, objects 
and persons.  

a

 

The field intensities of fixed transmitters, such as the base stations for the radio phones (cellular / wireless) and land mobile radios, amateur radio, AM and 

FM broadcasting and TV broadcasting, cannot be provided theoretically with accuracy. To evaluate the electromagnetic environment due to fixed RF transmit-
ters, it is advisable to consider an electromagnetic investigation on site. If intensity of the field, measured at the location where the XPERT UNIT

®

 motor is 

used, exceeds the applicable RF compliance level as above, it is advisable to monitor the XPERT UNIT

®

 motor to verify that its operation is normal. If abnormal 

performances are observed, then additional measures may be necessary, such as reorientation or relocation of the XPERT UNIT

®

 motor.  

Over the frequency range from 150 kHz to 80 MHz, it is advisable that field strengths are less than 3 V/m. 

 
 
 

 
 
 
 
 

Recommended separation distances between portable and mobile RF communication devices and the XPERT UNIT

®

 motor  

XPERT UNIT

®

 motor is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. Customer or user 

of the XPERT UNIT

®

 motor can contribute to prevent electromagnetic interferences by maintaining a minimum distance between the portable and 

mobile RF communication devices (transmitters) and the XPERT UNIT

®

 motor as recommended below, depending on the maximum transmission 

power.  

Separation distance depending on the transmitter frequency (m)  

Rated maximum output power of 
the transmitter in W  

From 150kHz to 80MHz 

d= 1.2

From 80MHz to 800MHz 

d= 0.4

From 800MHz to 2.7GHz 

d= 0.7

0.01 

0.12 

0.04 

0.07 

0.1 

0.38 

0.13 

0.22 

1.20 

0.40 

0.70 

10 

3.80 

1.30 

2.20 

100 

12.00 

4.00 

7.00 

19. ACCESSOIRIES 

Reference

 

 

Description  

XP411 

Motor support

 

XP412 

Clips for hanging of the irrigation line (x 10)

 

XP311L 

LED Micromotor

 

XP311 

Non-LED Micromotor

 

XP312 

Micromotor cable

 

XP313 

Micromotor 

XP UNIT 

non LED + cable

 

XP313L 

Micromotor 

XP UNIT 

LED + cable

 

XP216 

AC/DC charging adapter 8W-5V

 

(INPUT :100-240VAC;0.4A;50-60Hz / OUTPUT : 5.0VDC;1.6A)

 

XP415 

Bracket

 

110535 

Screen protection film (x 5)

 

1105310 

Screen protection film (x 10)

 

110545 

Micromotor protection casing (x 5)

 

1105410 

Micromotor protection casing (x 10)

 

110525 

Irrigation lines for bag or bottle (x 5)

 

1105210 

Irrigation lines for bag or bottle (x 10)

 

6841-0.5L 

0.9% NaCl bag / 0.5 litre

 

6841-0.5L_V 

0.9% NaCl bag / 0.5 litre (x20)

 

16400XL 

Implantology contra-angle light XS

 

16400X 

Implantology contra-angle XS

 

a

®

 

EN - 

USER GUIDE

 

Fr

an

çais

 

Engli

sh

  

D

eu

tsc

h

 

Esp

ol

 

Ita

li

an

o

 

Portu

gu

ês

 

Ne

d

erl

an

d

中国的

 

  

   رع

 

Содержание Xpert Unit

Страница 1: ...bcdef ghij EN User manual ...

Страница 2: ...at you have placed in it In order to get complete and sustainable benefit from this product it is recommended that you read this user manual first and perform the recommended inspection and maintenance tasks This Anthogyr product is used exclusively with the accessories provided by Anthogyr micromotor pedal power supply cable The use of any other accessory is prohibited This equipment is compatibl...

Страница 3: ...f the manufacturers for the instrumentation used This is to limit the risk of injury and deterioration of instruments ATTENTION Once the servicing work is completed switch off the device Unplug it from the electrical mains in the event of prolonged non use WARNING a EN USER GUIDE Français English Deutsch Español Italiano Português Nederlands 中国的 عر 4 2 5 Storage conditions 4 2 6 Peristaltic pump 4...

Страница 4: ...e Position 0 6 2 CONNECTION DISCONNECTION OF THE MICROMOTOR Align the red dot of the micromotor socket to the red dot of the connector on the front face of the cabinet and clipper Technical Specifications Dimensions Cabinet w x d x h 243 x 222 x 102 mm Pedal l x d x h 280 x 170 x 70 mm Micromotor Ø x l Ø23 x 115 mm Micromotor cable l 2 m Cabinet 2 5 kg Weight Pedal 1 kg Micromotor 110 g Micromotor...

Страница 5: ...position I At startup all the pictograms on the screen light up and the device emits a beep The code Er02002 at startup means there is an anomaly with the date and time The date and time synchronise automatically with the mobile app when you are connected 7 2 WIRELESS PEDAL CONNECTION 7 2 1 At the 1st use At unit startup the pictogram display means that the pedal is on standby Press on the pedal l...

Страница 6: ...ngles of the MontBlanc Implant series 10400X XL 16400X XL With these contra angles the accuracy of torque is 10 for the range from 5 to 80 N cm 8 3 SETTING THE VALUES OF SPEED TORQUE FLOW RATE 8 3 1 Setting the rotation speed and the maximum torque 1 Pressing on the parameter to be changed speed or torque 2 The parameter starts flashing and the buttons appear 3 Adjust the value of the parameter wi...

Страница 7: ... flashes indicating the need to recharge soon see instructions below When charge level of the battery reaches 0 the device will beep every 30 seconds and it is not possible to use the motor Recharge according to the following instructions 8 7 RECHARGING THE PEDAL BATTERY Connect the charging adapter to the pedal through the connector located at the rear of the pedal Connect the adapter to the main...

Страница 8: ...ect for a period of 24 months from the date of invoice This warranty does not apply to wearing parts Any modification or addition to the product without the express consent of the company Anthogyr will nullify this warranty The warranty will lapse in case of non observance of the technical instructions provided with all our devices Anthogyr cannot be held responsible for damages and their conseque...

Страница 9: ... problem per sists do not use the motor pedal micro motor any longer Contact the Anthogyr After Sales Service for more infor mation Er 02 005 The touch bar encounters operating problems The micromotor pedal micromotor assembly can still be used safely with the pedal to complete the ongoing care Er 02 006 Er 02 007 Update the cabinet software using the mobile application Er 04 006 Overheating of th...

Страница 10: ...use any interference in nearby electronic equipment XPERT UNIT motor is suitable for use in all premises including domestic premises and those directly connected to the low voltage public electricity supply network feeding the buildings for domestic use Directives and declaration of the manufacturer Electromagnetic immunity The XPERT UNIT motor is intended to be used in the environment specified b...

Страница 11: ...gths are less than 3 V m Recommended separation distances between portable and mobile RF communication devices and the XPERT UNIT motor XPERT UNIT motor is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled Customer or user of the XPERT UNIT motor can contribute to prevent electromagnetic interferences by maintaining a minimum distance between the ...

Страница 12: ...redits Anthogyr All rights reserved Not contractual photos 16313000_NOT_2019 07 A Anthogyr SAS 2 237 Avenue André Lasquin 74700 Sallanches France Tél 33 0 4 50 58 02 37 Fax 33 0 4 50 93 78 60 www anthogyr fr K ...

Отзывы: