4.3
Coding - plug bridges
STB1
Linf plug Position a
Brake function
A cut-off of the control voltage on connecting terminal 2-5 and/or X2-
6 causes the motor to come to a standstill. This is the normal
operation mode of the control device..
Link plug Position b with brake function for positioning
After the cut-off of the control voltage on connecting terminal X2-5
ad/or X2-6 the motor winding is short-circuited. The current
dependant of the braking energy and must not exceed 8 A because
otherwise the motor or the control device can be destroyed. If the
jumper is plugged in Position a, the manufacturer is not liable for
damages to the motor or the control device.
STB2
Link plug Position a
Relay function
The function set-actual monitoring has an effect upon the stand-by
signal output, this means that function result is UND-coupled.
Link plug Position b
The function set-actual monitoring has no effect upon the stand-by
signal output.
STB3
Link plug Position a
Set value source
The function fixed speeds is selected. Selection of the fixed speed
via connecting terminal X2-8.
HIGH = Selection fixed speed n2
LOW = Selection fixed speed n1
Plug bridge Position b
The function analog set value is selected.
Speed set value 0 ... 10 V to connecting terminal X2-8.
6
7
8
9
C 37
O
F
F
SET
n-
m
a
x
P
I
n2
n1
tH
tR
S
e
t
va
lu
e s
o
ur
c
e
(ST
B3
)
Re
la
y
fu
n
c
tio
n
(
ST
B
2
)
Br
a
k
e
(S
TB
1)
Er
ro
r
Se
t v
a
lu
e
n2
S
tan
d-
by
TM
b
a
X2