15
4- Us in standard mode
Starting Operation
Press “
“ button, and when the unit receives the signal, it gives out two“ beep “tones, the
operation is on and the heat pump water heater stars operation.
lf the interval shorter than 3 minutes from last shut down to the present switch-on, the compressor
only restarts after 3 minutes to protect the system.
Temperature Setting Selection
Press “
“ to set temperature 1 degree higher.
Press “
“to set temperature 1 degree lower
Temperature range set in heating mode: 10°C – 60°C. (Single water chlller without this function)
Setting right the hour of the Heat pump
The Heat pump must not run. If it is running. press on “ “ for stopping it.
Press 5 seconds on “ “, the left display ( = the hour) lights
Press the button ‘‘ “ or “ “ for increasing or decreasing the hour.
Press again on “ “, the left display ( = the minutes ) lights
Press the button “ “ or “ “ for increasing or decreasing the minutes.
Validate in pressing on “ “ ( or wait 10 seconds; the display will leave this setting mode by it self)
Setting of running selected periods (TIMER)
Press on “ “ , the left display (= the hour ) lights
Press the button “ “ or “ “ for increasing or decreasing the hour.
Press again on “ “. the left display ( =the minutes ) lights
Press the button “ “ or “ “for increasing or decreasing the minutes.
Validate in pressing on “ ‘‘; The light “ “switches on.
For setting the hour of stopping running (TIMER)
Press on “ “ and set the hour &he minutes as done before...
The light “ ‘‘ switches an.
Cancelling this programming
Press on “ “ The light “ “ light. Press on “ “
Press on “ “ The light “ “ light. Press on “ “
Coercive Defrosting
1. press “ “ ‚ Button, the heater go to defrost state.
2. After 3 minutes ‚when coil temperature up to 10°C or the time of defrost reaches 8 minutes, defrost
is stopped.
3. After exiting the state of defrost, ther heater will stop operation for 3 minutes, then it will run as
the state before defrost.
Or two figures on the right: desired temperature
Light of electric heater running
Button for coercive defrosting
It is used to ser up the function
of coercive defrosting.
Or two figures on the right: desired temperature
Button for coercive defrosting
It is used to ser up the function
of coercive defrosting.