ANTEK Green Energy AIR MAGNA 200 Скачать руководство пользователя страница 1

AIR MAGNA 200

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Содержание AIR MAGNA 200

Страница 1: ...AIR MAGNA 200 INSTALLATION AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...n the individuals the animals or the objects On no account the importer of this apparatus could not be made responsible for this damage Use of the heat pump this heat pump is intended exclusively with...

Страница 3: ...3 Electric connections 12 3 4 Running of reversible heat pump 13 3 5 Description of the screen of display and control 14 4 Use in standard mode 15 5 Instruction for the fitter 5 1 Devices of control a...

Страница 4: ...result in death Avertissement Any wrong handling can cause serious damage to the user and the machine TO NOT DO To follow attentively To be sure of the electric connections To be sure of the disconne...

Страница 5: ...all the button OFF Do not draw on the power supply cable Well have in hand the plug to disconnect it Fire hazard could occur due to the wrenching of the electric cable Do not touch the plug with wet...

Страница 6: ...heat pump 2 1 Outside 1 Power Plug 2 Control pannel 3 Air lnIet 4 Air Outlet 5 Temperature Sensor 6 Drainage hole 7 Cold Water Inlet 8 Hot Water Outlet 9 Service valve 10 solar coil inlet 11 solar coi...

Страница 7: ...r tank 20 Defrost sensor 34 7 Motor Capacitor 21 Assistant unit of air outlet 35 8 Compressor capacitor 22 Fan motor 36 9 Compressor 23 Electrical Box 37 10 Circuit Board 24 Circuit board base 38 11 C...

Страница 8: ...20 1430 1530 1760 695 695 1825 Air ducts Dimension mm 150 150 Net weight Gross weight kg 55 64 66 75 73 82 81 90 Water Connection Inch 1 1 Capacity of the water tank L 120 150 200 300 Power Suppy V Ph...

Страница 9: ...gram below The ventilator should not blow towards the windows or crossing place There must be more than 1 5M space on the top of the unit The fixing board of the unit must be fixed by bracket Connect...

Страница 10: ...ater in valve to fill water Meanwhile open the hot water out valve till water spill over from the hot water out valve It means the tank is full of water Close the tap water in valve check leakage by s...

Страница 11: ...ur choice Option B Installation in the laundry washing room Hot water heating from room air Optional use laundry drying decalcified water for steam iron Dehumidification Option C Installation in the s...

Страница 12: ...lawful protection Controller must be installed or indoor wall and the plane is easy for use Electric protection of which must lay out the heat pump circuit breaker curves D or standard fuse of protect...

Страница 13: ...sends it into the condenser exchanger where it loses its heat by transmitting it to the water und it comes in the liquid state it loses its pressure und cools again into the pressure reducer before r...

Страница 14: ...ng On off To adjust the hour To adjust the current hour and functionning timetable Button for Temperature up and down It sets the temperature of water and time of dose the heater Defrost Setting and E...

Страница 15: ...he minutes lights Press the button or for increasing or decreasing the minutes Validate in pressing on or wait 10 seconds the display will leave this setting mode by it self Setting of running selecte...

Страница 16: ...erence of compressor star 3 C to 15 C adjustable 3 After setting the value the defrosting setting will exit automatically after several seconds And the system will memorize the last value of each sett...

Страница 17: ...m begins to defrost if the following three terms are met in the same time a T4 7 C lasts for a while b compressor runs continuously for more than 5 minutes c compressor runs accumulative total for 45...

Страница 18: ...imes of T3 100 C in 24 hours E7 There is electric leakage in Compress or outdoor motor four way valve Recommendation Call your fitter to check or change the controller of flow 6 Instructions of mainte...

Страница 19: ...not up 1 C or temperature remain or down in a certain time the certain time 15 adjustable from 1 to 10 minutes windows default is 3 minutes then the heater will start until reach the setting temperatu...

Страница 20: ...agram HEATING COOLING Exchanger Exchanger Compressor Compressor Water Outlet Water tank Water tank Water Outlet Water Inlet Water Inlet Four way valve 2 Four way valve 1 Four way valve 1 Four way valv...

Страница 21: ...21 9 Wiring Diagram Without Water Tank Electrical Heater With Water Tank Electrical Heater...

Страница 22: ...om the low vat The black plastic conduit to evacuate the condensates is not connected or is stopped The condensates are entailed by the condensation of the humid air on the wings of the evaporator It...

Страница 23: ...23 Notice...

Страница 24: ...ANTEK INDUSTRIAL GROUP Office Boerhaavegasse 8A A 1030 Wien Office and Warehouse Donaul nde 11 A 2403 Regelsbrunn Tel 43 0 1 89 04 04 4 Fax 43 0 1 89 04 04 41 5 E Mail www info antek at www ANTEK Gree...