Antaira Technologies - Industrial Ethernet Switches
LNX-1204G-10G-SFP Hardware Manual V1.0
13
Caution:
•
Only use copper conductors, 125
°
C, tighten to 5 lbs.
•
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
•
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 lb.
•
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
2.8 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows
below in
Figure 2.8
. By inserting the wires, it will detect the fault status including power failure or
port link failure (managed industrial switch only) and form a normal open circuit. An example is
shown below in
Figure 2.8
.
Caution:
•
The wire gauge for the terminal block should range between 12 ~ 24 AWG.
•
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to
eliminate power fault alarm.
Attention:
•
Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
•
Si vous n'utilisez qu'une seule source d'alimentation, connectez les
broches 1 à 5 et les broches 2 à 6 pour éliminer l'alarme de panne de
courant.
2.9 Grounding Note
Figure 2.8
Wiring the Fault Alarm Contact