background image

Antaira Technologies - Industrial Ethernet Switches

LMX-1600G-M12-67 Series - Hardware Manual - v1.0.1

© Copyright 2022 Antaira Technologies, LLC

All rights reserved

This document contains information, which is protected by copyright. Reproduction, adaptation, or translation without

prior permission is prohibited, except as allowed under the copyright laws.

Trademark Information

Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the

trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered

trademarks of Wi-Fi Alliance. All other brand and product names are trademarks or registered trademarks of their

respective owners.

Notice:

Copyrights © 2022 by Antaira Technologies, LLC. All rights reserved. Reproduction, adaptation, or translation

without prior permission of Antaira Technologies, LLC is prohibited, except as allowed under the copyright laws.

Disclaimer

Antaira Technologies, LLC provides this manual without warranty of any kind, expressed or implied, including but not

limited to the implied warranties of merchantability and fitness for a particular purpose. Antaira Technologies, LLC may

make improvements and/or changes to the product and/or specifications of the product described in this manual, without

prior notice. Antaira Technologies, LLC will not be liable for any technical inaccuracies or typographical errors found in this

guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of

the manual. The information contained is subject to change without prior notice.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the

FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential

installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to

radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to

radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try

to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Содержание LMX-1600G-M12-67 Series

Страница 1: ...G M12 67 Series 16 Port Industrial M12 IP67 Waterproof Gigabit Light Layer 3 Managed Ethernet Switch with 16 10 100 1000Tx M12 Connectors X Coded 24 55VDC Power Input Hardware Manual Version 1 0 1 Aug...

Страница 2: ...of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodi...

Страница 3: ...nterf rences nuisibles la r ception radio ou t l vision ce qui peut tre d termin en teignant puis en rallumant l quipement l utilisateur est encourag essayer de corriger les interf rences par une ou p...

Страница 4: ...thernet Switches LMX 1600G M12 67 Series Hardware Manual v1 0 1 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact...

Страница 5: ...ription 9 2 1 Physical Dimensions 9 2 2 Front View Panel 10 2 3 LED Indicators 11 2 4 Reset to Default 12 2 5 Ethernet Ports 12 2 6 USB Port 14 2 7 Console Port 14 2 8 Power Inputs 15 2 9 Relay Contac...

Страница 6: ...industrial gigabit Ethernet switch that meets the high reliability requirements demanded by industrial applications Its M12 connectors ensure a tight and robust connection and it guarantees reliable...

Страница 7: ...l Diffserv IEEE 802 1q VLAN tagging port based VLAN support IGMP snooping v1 v2 v3 IGMP filtering throttling IGMP query up to 1024 group Supports IPv4 IPv6 RMON MIB II port mirroring event Syslog DNS...

Страница 8: ...entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet industriel seront d crits dans ce manuel d utilisation...

Страница 9: ...witches LMX 1600G M12 67 Series Hardware Manual v1 0 1 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 166 2mm x 295mm...

Страница 10: ...aira Technologies Industrial Ethernet Switches LMX 1600G M12 67 Series Hardware Manual v1 0 1 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Pa...

Страница 11: ...us Green On The system is ready and works fine No events are occurring Red Flashing Firmware upgrading On System booting or configured event happens Master Green On ERPS Owner Mode Ring Master is read...

Страница 12: ...8 Pin X Coded Female Connector Transmission rate 10 100 1000Mbps Prepare the M12 8 Pin X Coded Ethernet Port mating cable for Ethernet connection The M12 X Coded Ethernet ports are auto sensing for 10...

Страница 13: ...n 100 meters 328 ft long Minimum Wire Gauge 24AWG Maximum Transmission Length 100m 328ft Caution Please use copper conductors only Attention Veuillez utiliser uniquement des conducteurs en cuivre Caut...

Страница 14: ...is for configuration backup restore M12 connector M12 4 Pin A Coded female connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Table 2 3 USB port pinouts 2 7 Console Port It is an M12 5 Pin A Coded fema...

Страница 15: ...steps below to insert the power wire Step 1 Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with Power 1 V1 V1 and Power 2 V2 V2 Step 2 Tighten...

Страница 16: ...conditions below 1 No event after reboot 2 No event after reset the switch A connection of relay contact for fault alarm is shown below in Figure 2 5 Figure 2 5 Wiring the relay contact for fault alar...

Страница 17: ...ominal input current 5mA typical Max input current 8mA Table 2 7 Specification of DI As described in the Relay Contact section if the fault status happens you have to use DI function to reset the Faul...

Страница 18: ...ches loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 7 for example if Switch B has power failure the bypass fun...

Страница 19: ...1 Prepare 4 screws for mounting the switch to a wall Note Recommended use of the M5 screws Step 2 Based on the Figure 2 1 Physical Dimensions which is shown the positions of 4 screw holes on the left...

Страница 20: ...Antaira Technologies Industrial Ethernet Switches LMX 1600G M12 67 Series Hardware Manual v1 0 1 Figure 3 2 Position of the screw holes...

Страница 21: ...x 2 To hang the industrial Ethernet switch on a wall please refer to the Mounting Installation section 3 Power on the industrial Ethernet switch and then the power LED light will turn on If you need h...

Страница 22: ...or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter wi...

Страница 23: ...king Scheduler mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TF...

Страница 24: ...A 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX 4 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP67...

Страница 25: ...n RoHS Compliant Certifications FCC CE Railway EN50121 3 2 EN50121 4 Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antair...