2.4 Reset to Default
Please perform the steps below to reset the switch to factory default setting.
Step 1: Reverse the Tx & Rx of the console cable and plug it into the console port.
Step 2: Restart the power.
Step 3: The switch will start rebooting with the port LEDs flashing.
Step 4: When the status LED turns Green, the process is completed.
Step 5: Remove the reversed console cable.
2.5 Ethernet Ports
●
M12 Interface (Auto MDI/MDI-X)
○
Connection Format: M12 8-Pin X-Coded Female Connector
○
Transmission rate: 10/100/1000Mbps
Prepare the M12 8-Pin X-Coded Ethernet Port mating cable for Ethernet connection. The M12 X-Coded Ethernet ports are
auto-sensing for 10Base-T, 100Base-TX, or 1000Base-T devices connections. Auto MDI/MDI-X means that you can
connect to another switch or workstation without changing straight-through or crossover cabling. See pin assignment
shown in Table 2.2.
M12 8-Pin X-Coded Female Connector
Pinouts
10/100Base-T(X) Signal
1000Base-T Signal
1
Transmit Data + (TX+)
BI_DA+
2
Transmit Data - (TX-)
BI_DA-
3
Receive Data + (RX+)
BI_DB+
4
Receive Data - (RX-)
BI_DB-
5
BI_DD+
6
BI_DD-
7
BI_DC-
8
BI_DC+
Table 2.2 - Ethernet port pinouts
Note: