Antaira Technologies - Industrial Ethernet Switches
LMX-1600G-M12-67 Series - Hardware Manual - v1.0.1
●
Connection of Cables
Use the twisted-pair cable, category 5e or the above cabling for M12 port connections. The cable between the Ethernet
switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
○
Minimum Wire Gauge: 24AWG
○
Maximum Transmission Length: 100m (328ft)
Caution:
Please use copper conductors only.
Attention:
Veuillez utiliser uniquement des conducteurs en cuivre.
Caution:
Use conductors with insulation rated for at least 60°C.
Attention:
Utilisez des conducteurs dont l'isolation est d'au moins 60°C.
Caution:
Base the conductor ampacity on a maximum termination temperature of 60°C.
Attention:
Basez l'intensité du conducteur sur une température de terminaison maximale de 60°C.