background image

Antaira Technologies - Industrial Ethernet Switches 

LMX-0800 Series Hardware Manual V1.3 

iii 

 

 

 

FCC Warning 

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 

15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause 

harmful interference to radio communications if the equipment is not installed and used in accordance with the 

instructions. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 

measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user's 

authority to operate the equipment. 

 
 

 

CE Mark Warning 

 

This is a Class-A product. In a domestic environment this product may cause radio interference in which case the 

user may be required to take adequate measures. 

 
 

 

Industrial Ethernet Switches 

Industrial Grade Managed Ethernet Switches 

 

 

Hardware Manual 

Version 1.3 (July 2018) 

 

 

This manual supports the following models: 

 

LMX-0800 

 

LMX-0800-T 

 
 

 

This document is the current official release manual. Please check our website (

www.antaira.com

) for any 

updated manual or contact us by e-mail (

[email protected]

). 

Содержание LMX-0800 Series

Страница 1: ...Antaira Industrial Ethernet Switches LMX 1002C SFPeries User Manual V1 0 i LMX 0800 Series 8 Port Industrial Managed Ethernet Switches With 8 10 100Tx Ethernet Ports Version 1 3 Hardware Manual...

Страница 2: ...Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed unde...

Страница 3: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Страница 4: ...recaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 6 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs 8...

Страница 5: ...S SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMX 0800 series is compact IP30 rated and DIN rail...

Страница 6: ...ion Embedded 8 10 100Tx Fast Ethernet RJ45 Ports Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 12 48V...

Страница 7: ...If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring inst...

Страница 8: ...anual V1 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0800 series 8 port industrial managed Ethernet switches with 8 10 100Tx ports...

Страница 9: ...t Grounding Screw LED for PWR1 PWR2 and Fault LAN Port 5 8 10 100Tx Hard Physical Reset Button Console Port USB Backup LAN Port 1 4 10 100Tx LED for 10 100Tx network speed Status The Front Panel of LM...

Страница 10: ...ve port alarm is disabled Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 1 8 Left LE...

Страница 11: ...the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operations Users can use straight through cables see figure below for all...

Страница 12: ...er switch hub workstation etc must be less than 100 meters 328 ft in length 2 8 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire 1 Insert the positive and ne...

Страница 13: ...rm contact is shown below in Figure 2 8 Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate...

Страница 14: ...to install the DIN Rail bracket on the rear side of the industrialEthernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the oppo...

Страница 15: ...l mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the...

Страница 16: ...rial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how...

Страница 17: ...ches with 8 10 100Tx ports Standards IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx Fast Ethernet IEEE 802 3x Flow Control for Full Duplex IEEE 802 3ad Port Trunking with LACP IEEE 802 1...

Страница 18: ...ounting DIN Rail Mounting wall mounting optional Power Requirement Input Voltage 12 48VDC Redundant Input Power Connection 1 removable 6 contact terminal block Power Consumption 15 Watts Environmental...

Отзывы: