background image

Antaira Technologies - Industrial Ethernet Switches 

LMX-0800 Series Hardware Manual V1.3 

14 

 

 

IGMP Groups 

Up to 256 

 
 

Port Interface 

Ethernet (RJ45) Port 

8*10/100BaseTx auto negotiation speed, Full/Half duplex mode, 

and auto MDI/MDI-X connection 

Serial Console Port 

1*RS232 in RJ45 connector with console cable, 115.2Kbps, 

8,N,1 

Configuration Backup Port 

1*USB 2.0 

 
 

Protection 

Overload Current 

Present 

Power Reverse Polarity 

Present 

CPU Watch Dog 

Present 

Network Cable 

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable; 100Base-TX: 2- 

pair UTP/STP Cat. 5 cable. EIA/TIA-568 100-ohm (100m) 

 
 

 

Mechanical 

Characteristics 

LED Indicator 

Power Unit: P1 (Green), P2 (Green), fault (Red) 

Ethernet port: Link/active (Green), 10/100Mbps 

Housing 

Metal IP30 protection 

Dimension 

54 x 142 x 99 mm 

Weight 

Unit Weight: 2.0 lbs. Shipping Weight: 3.0 lbs. 

Mounting 

DIN-Rail Mounting, wall-mounting (optional) 

Power 

Requirement 

Input Voltage 

12~48VDC Redundant Input 

Power Connection 

1 removable 6-contact terminal block 

Power Consumption 

15 Watts 

 

Environmental 

Limits 

Operating Temperature 

STD: -10° to 70°C (14° to 158°F); 

EOT: -40° to 75°C (-40° to 167°F) 

Storage Temperature 

-40°C ~ 85°C (-40°F ~ 185°F) 

Ambient Relative Humidity 

5 to 95%, (non-condensing) 

 
 

Regulatory 

Approvals 

EMI 

FCC Class A 

EMS 

IEC6100-4-2/3/4/5/6/8; IEC6100-6-2; IEC6100-6-4 

 

Stability Testing 

IEC60068-2-32 (Free fall) 

IEC60068-2-27 (Shock) 

IEC60068-2-6 (Vibration) 

Safety 

UL 61010-1, UL 61010-2-201 

Table 5.1 - LMX-0800 Series Technical Specifications 

 
 

Antaira Customer Service and Support 

(Antaira US Headquarter) + 844-268-2472 

(Antaira Europe Office) + 48-22-862-88-81 

(Antaira Asia Office) + 886-2-2218-9733 

Please report any problems to Antaira: 

www.antaira.com 

[email protected]

 

www.antaira.eu 

[email protected]

 

 

www.antaira.com.tw 

[email protected]

 

 

Any changes to this material will be announced on the Antaira website. 

Содержание LMX-0800 Series

Страница 1: ...Antaira Industrial Ethernet Switches LMX 1002C SFPeries User Manual V1 0 i LMX 0800 Series 8 Port Industrial Managed Ethernet Switches With 8 10 100Tx Ethernet Ports Version 1 3 Hardware Manual...

Страница 2: ...Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed unde...

Страница 3: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Страница 4: ...recaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 6 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs 8...

Страница 5: ...S SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMX 0800 series is compact IP30 rated and DIN rail...

Страница 6: ...ion Embedded 8 10 100Tx Fast Ethernet RJ45 Ports Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 12 48V...

Страница 7: ...If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring inst...

Страница 8: ...anual V1 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0800 series 8 port industrial managed Ethernet switches with 8 10 100Tx ports...

Страница 9: ...t Grounding Screw LED for PWR1 PWR2 and Fault LAN Port 5 8 10 100Tx Hard Physical Reset Button Console Port USB Backup LAN Port 1 4 10 100Tx LED for 10 100Tx network speed Status The Front Panel of LM...

Страница 10: ...ve port alarm is disabled Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 1 8 Left LE...

Страница 11: ...the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operations Users can use straight through cables see figure below for all...

Страница 12: ...er switch hub workstation etc must be less than 100 meters 328 ft in length 2 8 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire 1 Insert the positive and ne...

Страница 13: ...rm contact is shown below in Figure 2 8 Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate...

Страница 14: ...to install the DIN Rail bracket on the rear side of the industrialEthernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the oppo...

Страница 15: ...l mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the...

Страница 16: ...rial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how...

Страница 17: ...ches with 8 10 100Tx ports Standards IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx Fast Ethernet IEEE 802 3x Flow Control for Full Duplex IEEE 802 3ad Port Trunking with LACP IEEE 802 1...

Страница 18: ...ounting DIN Rail Mounting wall mounting optional Power Requirement Input Voltage 12 48VDC Redundant Input Power Connection 1 removable 6 contact terminal block Power Consumption 15 Watts Environmental...

Отзывы: