The following figures show the cabling schematics for straight-through and crossover.
Figure 2.4
Figure 2.5
Straight-Through Cable Schematic
Crossover Cable Schematic
2.7 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ-45 port connections.
The cable between the switch and the link partner (switch, hub, workstation, etc.) must be less
than 100 meters (328 ft.) in length.
2.8 Wiring the Power Inputs
Caution: Please follow the steps below when inserting the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.6.
Figure 2.6 - Power Terminal Block
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7.
Figure 2.7 - Power Terminal Block
Note
Only use copper conductors, 60/75°C, tighten to 5lbs.
The wire gauge for the terminal block should range between 18~20
AWG.