background image

Antaira Technologies - Industrial Ethernet Switches 

LMP-0601G-SFP-V2 Series Hardware Manual V1.0 

 

 

 

 

IGMP snooping v1/v2, IGMP filtering / throttling, IGMP query up to 256 group 

 

Supports IPv4/IPv6, RMON, MIB II, port mirroring, event syslog, DNS, NTP/SNTP, 

HTTPS, SSH/SSL, TFTP 

 

MODBUS TCP for SCADA system integration 

 

Port Configuration

 

  Status, statistics, mirroring, rate limiting, event syslog 

 

Event Handling

 

  Event notification by Email: Cold/Warm Start, Power Failure, Authentication, SNMP 

trap and Fault Alarm Relay Output 

 

Software Upgrade via TFTP and HTTP

 

 

Configuration Backup 

– USB Port

 

 

 

1.3 Product Hardware Features 

 

System Interface and Performance

 

 

All RJ45 ports support Auto MDI/MDI-X Function 

 

Embedded 4*10/100/1000Tx (PSE: 30W/Port) RJ45 ports, 1*10/100/1000Tx RJ45 port, 

and 1*100/1000 SFP slot 

 

Store-and-forward switching architecture 

 

8K MAC address table 

 

Power line EFT protection: 2,000VDC; Ethernet ESD protection: 6,000VDC 

 

Power Input

 

 

DC 48~55V redundant, with a 6-pin removal terminal block 

 

It is recommended to use a UL listed industrial power supply 

 

Operating Temperature

 

 

Standard operating temperature model: -10°C to 70°C 

 

Extended operating temperature model: -40°C to 75°C 

 

Case/Installation

 

 

IP30 protection 

 

DIN-Rail and wall mount design 

 

 

 

 

 

 

 

Содержание LMP-0600 Series

Страница 1: ... 1204G SFP Series User Manual V2 1 i LMP 0601G SFP V2 Series 6 Port Industrial PoE Managed Ethernet Switch w 4 10 100 1000Tx 30W Port 1 10 100 1000Tx and 1 100 1000 SFP Slot 48 55VDC Power Input Version 2 Hardware Hardware Manual Version 1 0 October 2019 ...

Страница 2: ...wners Notice Copyrights 2019 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantabil...

Страница 3: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced rad...

Страница 4: ...ety Precaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inputs 8 2 9 Wiring the Fault Alarm Contact 9 2 10 Grounding Note 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 4 2 Maint...

Страница 5: ...thernet Ring Protection Switch protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMP 0601G SFP V2 series is IP30 rated and DIN rail mountable There are also two wide operating temp...

Страница 6: ... Upgrade via TFTP and HTTP Configuration Backup USB Port 1 3 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx PSE 30W Port RJ45 ports 1 10 100 1000Tx RJ45 port and 1 100 1000 SFP slot Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Powe...

Страница 7: ...able 1 5 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Warning Labels The caution label means that you should check the certain information on user manual when working ...

Страница 8: ...1G SFP V2 Series Hardware Manual V1 0 4 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0601G SFP V2 series W x D x H is 54mm x 99mm x 142mm Figure 2 1 LMP 0601G SFP V2 Series Physical Dimensions ...

Страница 9: ...pped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure2 3 Top Panel View of LMP 0601G SFP V2 Series 6 Pin Removal Terminal Block Grounding Screw Reset Button LAN 1 4 LED for Link Activity Status 10 100 1000Mbps LAN 1 4 LED for PoE Status LED for Power 1 Power 2 Fault Master and Ring Console Port USB for Configuration SFP Port 6 LED for Link Activity Status 10...

Страница 10: ...re Red Preconfigured alarms are detecting failure Off Switch is in the process of booting Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active Fiber Port 5 6 Link ACT Green On Connected to Network 100Mbps Flashing Network is active Off Not connected to network LAN Port 1 4 Upper LED Green On Connec...

Страница 11: ...nections Auto MDI means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover cabling schematics RJ 45 Pin Assignments Pin Number Assignment 1 Rx 2 Rx 3 Tx 6 Tx Table 2 3 RJ45 Pin Assignments Note The and signs represent the polarity of the wires that make up each wire pair Al...

Страница 12: ... Schematic Figure 2 5 Crossover Cable Schematic 2 7 Cabling Use the four twisted pair category 5e or the above cabling for the RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft in length 2 8 Wiring the Power Inputs Please follow the steps below when inserting the power wire 1 Insert the positive and negative wire...

Страница 13: ...gauge for the terminal block should range between 12 24AWG 2 10 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown blow in Figure 2 15 Figure 2 15 Grounding screw Caution Using a shielded cable achiev...

Страница 14: ...side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 ...

Страница 15: ... wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opp...

Страница 16: ...ease refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section...

Страница 17: ...nical Specifications Table 5 1 has the technical specifications for Antaira s LMP 0601G SFP V2 series Technology L2 Switching Port MAC Protocol IP Subnet based VLAN VLAN trunking GARP GVRP Loop Guard Link Aggregation static LACP BPDU guard Error disable recovery IGMPv2 snooping MLD snooping IGMP filtering IPMC throttling filtering leave proxy DHCP snooping ARP MEP G 8032 v1 v2 L3 Switching DHCP op...

Страница 18: ...Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP30 protection Dimensions 54 x 142 x 99 mm W x H x D Weight Unit 1 9 lbs Shipping 2 7 lbs Mounting DIN Rail Wall mount Optional Power Requirement Input Voltage 48 55VDC Redundant Input Power Connection 1 r...

Страница 19: ...6 8 Free Fall Shock Vibration IEC60068 2 32 IEC60068 2 27 IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 LMP 0601G SFP V2 Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support a...