Figure 2.5 - Power Terminal Block
2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.6.
Figure 2.6 - Power Terminal Block
Caution:
Only use copper conductors, 125°C, tighten to 5 lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 lb.
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
2.9 Grounding Note
Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference (EMI). Run the ground
connection from the ground screw to the grounding surface prior to connecting devices. The grounding screw symbol is
shown below in
Figure 2.7
.
Figure 2.7 - Grounding Screw Symbol
Caution: Using a shielded cable achieves better electromagnetic compatibility.