background image

Antaira Technologies - Industrial Media Converters
IMC-C1000-XX Series - Hardware Manual - v1.2

© Copyright 2021 Antaira Technologies, LLC

All rights reserved

This document contains information, which is protected by copyright. Reproduction, adaptation, or translation without

prior permission is prohibited, except as allowed under the copyright laws.

Trademark Information

Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the

trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered

trademarks of Wi-Fi Alliance. All other brand and product names are trademarks or registered trademarks of their

respective owners.

Notice: Copyrights © 2021 by Antaira Technologies, LLC. All rights reserved. Reproduction, adaptation, or translation

without prior permission of Antaira Technologies, LLC is prohibited, except as allowed under the copyright laws.

Disclaimer

Antaira Technologies, LLC provides this manual without warranty of any kind, expressed or implied, including but not

limited to the implied warranties of merchantability and fitness for a particular purpose. Antaira Technologies, LLC may

make improvements and/or changes to the product and/or specifications of the product described in this manual, without

prior notice. Antaira Technologies, LLC will not be liable for any technical inaccuracies or typographical errors found in this

guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of

the manual. The information contained is subject to change without prior notice.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the

FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential

installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to

radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to

radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try

to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Содержание IMC-C1000 Series

Страница 1: ...IMC C1000 XX Series Compact Industrial Gigabit Ethernet Media Converter with 10 100 1000Tx to 1000Fx SC ST Connector 12 48VDC Power Input Hardware Manual Version 1 2 May 2021...

Страница 2: ...the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodicall...

Страница 3: ...nterf rences nuisibles la r ception radio ou t l vision ce qui peut tre d termin en teignant puis en rallumant l quipement l utilisateur est encourag essayer de corriger les interf rences par une ou p...

Страница 4: ...0 S4 T IMC C1000 S6 IMC C1000 S6 T IMC C1000 ST M IMC C1000 ST M T IMC C1000 ST S1 IMC C1000 ST S1 T IMC C1000 WA S1 IMC C1000 WA S1 T IMC C1000 WB S1 IMC C1000 WB S1 T This document is the current of...

Страница 5: ...tion 3 2 1 Physical Dimensions 3 2 2 Front View Panel 4 2 3 Top View Panel 4 2 4 LED Indicators 5 2 5 DIP Switch Setting 5 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wiring the Power Inputs 7 2 9 Groundin...

Страница 6: ...ion This product series supports DIN rail as well as wall mountable orientations and provides operating temperature range models in STD 10 C to 70 C and EOT 40 C to 80 C 1 1 Product Hardware Features...

Страница 7: ...ispositif de protection sur l entr e d alimentation Les sp cifications mat rielles du convertisseur de m dia industriel les ports les informations de c blage et l installation du c blage seront d crit...

Страница 8: ...a Converters IMC C1000 XX Series Hardware Manual v1 2 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 26mm x 95mm x 75...

Страница 9: ...Figure 2 2 below shows the top panel of the product series Figure 2 2 Top View Panel 2 3 Top View Panel Figure 2 3 below shows the top panel of the IMC C1000 XX series media converter that is equipped...

Страница 10: ...twork 1000Mbps Flashing Networking is active Off Not connected to network LAN Port Lower LED Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network Table 2...

Страница 11: ...rossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2...

Страница 12: ...e mode When connecting the fiber port to another one please follow Figure 2 4 to connect accordingly Wrong connection will cause the port to work abnormally Figure 2 4 SC Connector Caution This is a C...

Страница 13: ...range between 18 20 AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C serrez 5 lb Le calibre des fils du bornier doit tre compris entre 18 et 20 AWG 2 9 Grounding Note Grounding and w...

Страница 14: ...Antaira Technologies Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 Attention L utilisation d un c ble blind permet une meilleure compatibilit lectromagn tique 9...

Страница 15: ...rear side of the industrial media converter Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To...

Страница 16: ...industriel 1 Remove the DIN Rail bracket from the industrial media converter by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial media converter 3 Use t...

Страница 17: ...Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 Figure 3 4 Remove DIN Rail bracket Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Br...

Страница 18: ...ter please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial media converter please refer to the Wall Mounting section for wall mounting i...

Страница 19: ...dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment...

Страница 20: ...ssure flow control Switch Properties Memory Buffer 1Mbit Jumbo Frame 10Kbytes MAC Table Size 8K Interface Ethernet Port 1 RJ45 Port w 10 100 1000T X Auto negotiation speed Full Half duplex mode and au...

Страница 21: ...ent Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE EN55024 EN61000 6 2 EN61000 4 2 3 4 5 6 8 Free Fall IEC60068 2...

Страница 22: ...ntaira Technologies Industrial Media Converters IMC C1000 XX Series Hardware Manual v1 2 www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 17...

Отзывы: