Balance Charger xMove 2.0/xBase 2.0
9
6. Lithium Battery (Lilo/LiPo/LiFe) Program
7. Charging Lithium Batteries
8. Charging Lithium Battery at Balance
Mode
These program is only suitable for charging and discharging Lithium
batteries with a nominal voltage of 3.3 V, 3.6 V and 3.7 V per cell.
These batteries need to adopt different charge technique is termed a
constant voltage (CV) and constant current (CC) method. The charge
current varies according to the battery capacity and performance.
The final voltage of the charge process is also very important; it
should be precisely matched with the charade voltage of the battery.
They are 4.2 V for LiPo, 4.1 V for Lilo, and 3.6 V for LiFe.
The charge current and nominal voltage as for cell count set on the
charge program must always be correct for the battery to be charged.
When you are willing to alter the parameter value in the program,
press “Start/Enter” key to make it blink, then change the value with
INC ► or ◄ DEC key. The value will be stored by pressing “Start/
Enter” key once.
This is for balancing the voltages of Lithium batteries of a battery
pack to be charged. To do this, the battery pack being charged should
have the individual cell connector. And connect it to the individual
port at the right side of the charger with a suitable connection cable
that fits with your battery pack. And also, you need to connect the
battery output to the output of charger.
In this mode, the charging process will be different form ordinary
charging mode. The internal processor of the charger will minitor the
voltages of each cell of the battery pack and controls the charging
current that is feeding to each cell to normalize the voltage.
The left side of the first line shows the type of battery you select at
the users setting. The value on the left side of the second line sets a
change current, and the value on the right side of the second line sets
the voltage of the battery pack.
After setting the current and voltage press “Start/Enter” key for more
than 3 seconds to start the process.
(Charge current: 0.1–5.0 A, Voltage: 1–6 series).
This shows the number of cells you set up and the processor detects.
‘R’ shows the number of cells found by the charger and ‘S’ is the
number of cells selected by you at the previous screen. If both
numbers are identical you can start charging by press “Start/Enter”
button. If not, press “Batt type/Stop” button to go back to previous
screen. The carefully check the number of cells of the battery pack to
charge again.
The screen shows the present situation during change process. To stop
charging press “Batt type/Stop” key once.