5. Initial Parameter Set Up (Users set up)
xMove 2.0/xBase 2.0 will be operated with the default value of the
essential user settings when it is connected to a 12 V battery or a AC
wall socket for the fist time. The screen displays the following infor-
mation in sequence and the user can change the value of parameter
on each screen.
When you are willing to alter the parameter value in the program,
press “Start/Enter” key to make it blink, then change the value with
INC ► or ◄ DEC key. The value will be stored by pressing “Start/
Enter” key once.
The screen displays the nominal voltage of lithium battery. There are
three kinds of lithium batteries: LiFe (3.3 V), LiLo (3.7 V) or LiPo
(3.7 V). This is very important so you have to check the battery
carefully and set it up correctly. If it is different from correct value the
battery can explode during charge process.
xMove 2.0/xBase 2.0 recongnises the cell count of lithium battery
automatically at the beginning of the charge or discharge process
to avoid from erroneous settings by the user. But deeply discharged
batteries can be perceived incorrectly. To prevent the error, you can
set time term to the verify the cell count by the processor.
Normally, 10 minutes are enough, to perceive the cell count correctly.
For the battery of larger capacity, you may extend the time term. But
if you set the time term too long for the battery of smaller capacity,
the charge or discharge process can be finished within the time term
with the erroneous cell count. This may cause a fatal result. If the
processor recognizes the cell count incorrectly at the beginning of the
charge or discharge process, you may extend the time. Otherwise,
you had better used the default value.
This shows the trigger voltage for automatic charge termination of
NiMH and NiCd batteries. The effective value ranges form 5 to
20 mV per cell. If the trigger voltage is set higher, there is a danger
of overcharging the battery; if it is set lower, there is a possibility of
premature termination. Please refer the technical specification of the
battery (NiCd default:12 mV, NiMH default: 7 mV).
You can select the function of the 3-pin port at the left side of the
unit. It can be used as temperature sensor port or as USE port,
selected at this screen. If the port is assigned as a temp. port, an
optional temperature probe contacting the surface of battery can be
used. When it is selected as an USB port, you can link the charger
to your PC via an optional USB cable. This can utilize the optional
software that can show you the charge process at PC.
You can set the maximum temperature at which the charger should
allow battery to reach during charge. Once a battery reaches this
temperature during charge, the process will be terminated to protect
the battery.