16. Charge-to-Discharge & Discharge-to-
Charge Cycle NiMH/NiCd Battery
17. Pb (lead-sulphuric acid) Battery
Program
Set the sequence on the left and the number of cycle on the right.
You can use this function for balancing, refreshing and break-in the
battery. To avoid rising temperature of the battery, there will a brief
cool-off period that already fixed at ‘User setting’ after each charge
and discharge process. The cycling number ranges from 1 to 5.
To stop the process, press “Batt type/Stop” key once.
You can change the discharge or charge current by pressing
“Start/Enter” key once during the process. The audible sound
indicates you the end of process.
At the end of the process, you can see charged or discharged electric
of the battery at each cyclic process.
By pressing INC ► or ◄ DEC button, the screen shows the result of
each cycle in order.
This is program for charging Pb (lead-sulphuric acid) battery with
nominal voltage from 2 to 20 V. Pb batteries are totally different
from NiCd or NiMH batteries. They can only deliver relatively lower
current compared to their capacity, and similar restrictions definitely
apply to charge. So the optimal charge current will be 1/10 of the
capacity. Pb batteries must not be charged rapidly. Always follow the
instruction is supplied by the manufacturer of battery.
When you are willing to alter the parameter value in the program,
press “Start/Enter” key to make it blink then change the value with
INC ► or ◄ DEC key. The value will be stored by pressing
“Start/Enter” key once.