Balance Charger xMove 2.0/xBase 2.0
19
23. Warning and Error Messages
xMove 2.0/xBase 2.0 incorporates various functions of protective
and monitoring the system to verify functions and the state of its
electronics. In any case of occurring error, the screen displays the
cause of error that is self-explanatory with audible sound.
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between the battery and the output or voluntarily
disconnecting the charge lead during the operation of charge or
charge or discharge on output.
There was a short-circuit at OUTPUT. Please check the charging leads.
The voltage of input power drops below the limit.
The voltage of Lithium battery pack was selected incorrectly.
Verify the voltage of battery pack carefully.
There happens the malfunction at the charger circuit by any reason.
The processor detects the voltage is lower than you set at Lithium
program. Please check the cell count of the battery pack.
The processor detects the voltage is higher than you set at Lithium
program. Please check the cell count of the battery pack.
The voltage of one of the cells in the Lithium battery pack is too low.
Please check the voltage of the cells one by one.
The voltage of one of the cells in the Lithium battery pack is too high.
Please check the voltage of the cells one by one.
There are bad connection at the individual connector. Please check the
connector and cables carefully.
The internal temperature of the unit goes too high. Cool down the
unit.
The processor cannot continue to control the feeding current by any
reason. The unit needs to be repaired.