EN
101
ANSLUT 41612
1
Heat Pump Space Heater
Outdoor
41612
1
Indoor
41612
1
Air-to-water heat pump
Yes
Water-to-water heat pump
No
Brine-to-water heat pump
No
Low Temperature heat pump
Yes
Equipped with a supplementary
heater
No
Heat pump combination heater
No
Parameters shall be declared for medium temperature application, except for low temperature heat pumps. For low temperature heat pumps,
parameters shall be declared for low-temperature application
Parameters shall be declared for average climate conditions
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated Heat Output(³)
Prated
3.26
kW
Seasonal space heating energy
efficiency
Ƞ
s
125
%
Declared capacity for heating for part load at indoor temperature 20°C
and outdoor temperature T
j
Declared capacity for heating for part load at indoor temperature 20°C
and outdoor temperature T
j
T
j
= - 7
Pdh
2.72
kW
T
j
= - 7
COPd or
PERd
2.28
- or %
T
j
= + 2
Pdh
2.72
kW
T
j
= + 2
COPd or
PERd
2.84
- or %
T
j
= + 7
Pdh
2.44
kW
T
j
= + 7
COPd or
PERd
4.45
- or %
T
j
= + 12
Pdh
2.83
kW
T
j
= + 12
COPd or
PERd
5.72
- or %
T
j
= bivalent temperature
Pdh
2.76
kW
T
j
= bivalent temperature
COPd or
PERd
2.39
- or %
T
j
= operation limit temperature
Pdh
2.21
kW
T
j
= operation limit temperature
COPd or
PERd
1.92
- or %
For air-to-water heat pumps: T
j
= -
15°C (if TOL<-20°C)
Pdh
kW
For air-to-water heat pumps: T
j
= -
15°C (if TOL<-20°C)
COPd or
PERd
- or %
Bivalent Temperature
T
biv
-6
°C
For air-to-water heat pumps:
Operating limit temperature
TOL
-10
°C
Cycling interval capacity for heating
Pcych
kW
Cycling interval efficiency
COPcyc or
PERcyc
- or %
Degradation co-efficient
Cdh
1.0
-
Heating water operating limit
temperature
WTOL
52
°C
Power Consumption in modes other than active mode
Supplementary heater
Off Mode
P
OFF
0.013
kW
Rated heat output
Psup
1.05
kW
Thermostat off mode
P
TO
0.040
kW
Electricity
Standby mode
P
SB
0.014
kW
Type of energy input
Crankcase heater mode
P
CK
0.033
kW
Other Items
Inverter
Capacity Control
Variable
For air-to-water heat pumps: Rated
air flow, outdoors
-
1750
m³/h
Sound power level, indoor/outdoor
L
WA
42/ 62 dB
For water- or brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
-
m³/h
Annual energy consumption
Q
HE
2122
kWh
For heat pump combination heater
Declared load profile
Water heating energy efficiency
Ƞ
wh
%
Daily Electricity consumption
Q
elec
kWh
Daily fuel consumption
Q
fuel
kWh
Annual electrical consumption
AEC
kWh
Annual fuel consumption
AFC
GJ
(³) For heat pump space heaters and heat pump combination heaters, the rated heat output
Prated
is equal to the design load for heating
Pdesignh
,
and the rated heat output of a supplementary heater
Psup
is equal to the supplementary capacity for heating
sup(Tj).
(⁴) If Cdh is not determined by measurement the the default degradation coefficient is Cdh = 0.9
Содержание 416121
Страница 3: ...1 2 1 1 1 2 2 7 3 4 5 6...
Страница 4: ...4 5 6 3 1 2 3 4 5 6 12 7 8 9 11 10...
Страница 5: ...4 2 5 2 1 5 3 3 3 5 6 4 2 5 2 1 3 3 3 7 8...
Страница 6: ...1 6 4 2 3 1 4 2 5 3 9 10...
Страница 7: ...11 12 14 13 1 2...
Страница 8: ...18 15 17 16 1 3 2 4 5 6 6 1 1 2 3 4 5...
Страница 9: ...19 20 21 1 2...
Страница 10: ...22 24 23...
Страница 11: ...25 26...
Страница 12: ...29 28 27 30 31 T6 12 m 12 m T6 T6 T6...
Страница 13: ...32 33 A B C D E F...
Страница 14: ...34 35 1 24 C 2 29 C 3 33 C 4 38 C 5 42 C SET TEMP Temp 6 47 C 50 C 7 8 9 10 SET TEMP Temp Max temp Max temp...
Страница 15: ...36 38 37 50 C 11 12 13 14 15 SET TEMP Temp Max temp...
Страница 16: ...39 40 41 A B...
Страница 17: ...A B 42 43...