Site Master User Guide
PN: 10580-00252 Rev. J
7-1
Chapter 7 — Ethernet Connectivity
(Option 411)
7-1
Introduction
This chapter describes how to connect to a network or directly to a PC using Option 411
Ethernet Connectivity. It also describes the RJ-45 connector, DHCP, and connection tests for
the Site Master.
7-2
Ethernet Connection
Network Connection
Use the following procedure if you can connect to a network that offers DHCP.
1.
Connect the handheld instrument and the computer running MST to the Ethernet
network.
2.
Turn on the Anritsu handheld and confirm the network connection from the
System
main menu (Shift+8) >
Status
submenu key. The IP address on the handheld is
displayed in the STATUS window.
3.
In Master Software Tools, press the
Network
tab then the
Query Network for Instruments
button. Double-click on the handheld instrument to complete the connection. The
instrument model and IP address along with a green connection icon will be displayed
at the top of the MST window.
Ethernet Direct Connection
Use the following procedure if you can not connect to a network running DHCP.
1.
Connect the handheld instrument and the computer running MST with an Ethernet
crossover cable or a standard Ethernet cable with a crossover adapter.
2.
Turn on the Anritsu handheld and set the Ethernet connection to
Manual
.
System
main menu >
System Options
>
Ethernet
.
3.
Use the
Field
and
Octet
submenu keys to setup the following:
IP:
10.0.0.2
Gateway:
10.0.0.2
Subnet:
255.255.255.0
Press
Enter
to save the changes.
Note
DHCP is the default Ethernet type. If the Anritsu handheld has been set to Manual,
change to DHCP from the
System
main menu (
Shift
+8) > System Options >
Ethernet.
Содержание s332e
Страница 2: ......
Страница 46: ...3 6 Useful MST Utilities Quick Start Guide 3 16 PN 10580 00252 Rev J Site Master User Guide ...
Страница 70: ...5 6 Updating the Site Master Firmware System Operations 5 10 PN 10580 00252 Rev J Site Master User Guide ...
Страница 84: ...7 10 PN 10580 00252 Rev J Site Master User Guide ...
Страница 86: ...Bias Tee Option 10 8 2 PN 10580 00252 Rev J Site Master User Guide ...
Страница 98: ...Measurement Guides A 2 PN 10580 00252 Rev J Site Master User Guide ...
Страница 101: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 P N 10000 00000 Revision Prelim Printed December 2015 ...