background image

Setting Up Limit Lines

Spectrum Master UG

PN: 10580-00277  Rev. E

3-7

3-6

 Setting Up Limit Lines  

Press the 

Shift

 key then the 

Limit

(6) key on the numeric keypad to display the Limit menu.

Simple Limit Line

Spectrum Analyzer and Interference Analysis Modes

1. 

Press the 

Shift

 key and then the 

Limit

(6) key. 

2. 

Press the 

Limit (Upper / Lower)

 submenu key to select the desired limit line, Upper or 

Lower.

3. 

Activate the selected limit line by pressing the 

On Off

 submenu key so that 

On

 is 

underlined.

4. 

Press the 

Limit Move

 submenu key to display the Limit Move menu. Press the 

Move Limit

 

submenu key to change the dBm level of the limit line.

5. 

Press the 

Back

 submenu key to return to the Limit menu.

6. 

If necessary, press the 

Set Default Limit

 submenu key to redraw the limit line in view.

Limit Line Envelope

Spectrum Analyzer and Interference Analysis Modes 

Using Limit Envelope:

1. 

Press the 

Shift

 key and then the 

Limit

(6) key. 

2. 

Press the 

Limit (Upper / Lower)

 submenu key to select the desired limit line, Upper or 

Lower.

3. 

Press the 

Limit Envelope

 submenu key to display the Limit Envelope menu.

4. 

Press the 

Create Envelope

 submenu key to create an envelope around the measurement.

5. 

Press 

Upper Points

 or 

Lower Points

 submenu key to change the number of segments in 

the envelope.

6. 

Press the 

Upper Shape

 or 

Lower Shape

 submenu key to toggle between square and 

sloped limit envelope.

7. 

Adjust the Upper or Lower Offset to move the limit line closer to (a smaller value) or 
further away from the trace.

Содержание MS2722C

Страница 1: ...t of supplemental documentation for the Spectrum Master features and options The additional documentation is available as PDF files on the Documentation disc or the Anritsu Web site Anritsu Company 49...

Страница 2: ...LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFI...

Страница 3: ......

Страница 4: ...of Australia and New Zealand in order to indicate that these products conform to the EMC regulations of Australia and New Zealand Notes On Export Management This product and its manuals may require a...

Страница 5: ......

Страница 6: ......

Страница 7: ...labels attached to products that are not shown in the diagrams in this manual This indicates a prohibited operation The prohibited operation is indicated symbolically in or near the barred circle This...

Страница 8: ...is equipment presenting a risk of severe injury or fatal electric shock to untrained personnel In addition there is a risk of damage to precision components Caution Electrostatic Discharge ESD can dam...

Страница 9: ...e Documents 1 7 1 13 Anritsu Service Centers 1 7 1 14 Battery Replacement 1 8 1 15 Soft Carrying Case 1 9 1 16 Tilt Bail Stand 1 10 1 17 Secure Environment Workplace 1 10 Option 7 Secure Data 1 10 Spe...

Страница 10: ...3 2 Editing and Entering Values 3 2 Selecting the Analyzer Mode 3 2 3 3 Set the Measurement Frequency 3 3 Using Start and Stop Frequencies 3 3 Entering Center Frequency 3 3 Selecting Signal Standard 3...

Страница 11: ...u Overview 4 6 4 4 File Menu 4 7 Save Menu 4 8 Save Location Menu 4 9 Save On Event Menu 4 10 Recall Menu 4 11 Copy Menu 4 12 Delete Menu 4 13 Chapter 5 System Operation 5 1 Introduction 5 1 5 2 Syste...

Страница 12: ...re 7 2 Update Firmware by Using a USB Device 7 6 Appendix A Measurement Guides A 1 Introduction A 1 A 2 Documents Firmware Supplemental Information A 1 Appendix B Error Messages B 1 Introduction B 1 B...

Страница 13: ...MS2726C Refer to Appendix A Measurement Guides for additional information Throughout this manual these instruments may be referred to as a Spectrum Master or as a model MS2722C MS2723C MS2724C MS2725C...

Страница 14: ...2 Available Options Sheet 1 of 2 MS2722C xxxx MS2723C xxxx MS2724C xxxx MS2725C xxxx MS2726C xxxx Description 0007 Secure Data Operation 0019 High Accuracy Power Meter sensor not included 0031 GPS Rec...

Страница 15: ...dulation Measurements 1 0556 TD LTE Over the Air Measurements 1 0033 cdmaOne CDMA2000 1X Over the Air Measurements 2 0042 cdmaOne CDMA2000 1X RF Measurements 1 0043 cdmaOne CDMA2000 1X Demodulation 1...

Страница 16: ...used for bulk measurement storage The bright daylight viewable high resolution color liquid crystal display LCD provides easy viewing in a variety of lighting conditions The Spectrum Master is capabl...

Страница 17: ...ent results Although the Spectrum Master does not require daily field calibration Anritsu Company recommends annual calibration and performance verification by local Anritsu service centers 1 10 Preve...

Страница 18: ...Operators should exercise practices outlined within industry standards such as JEDEC 625 EIA 625 MIL HDBK 263 and MIL STD 1686 which pertain to ESD and ESDS devices equipment and practices Because th...

Страница 19: ...e bottom of each Spectrum Master web page presents Internet links to related literature and software Examples include the following types of documents Application Notes Brochures Data Sheets Instructi...

Страница 20: ...charged while it is installed in the Spectrum Master by using either the AC DC Adapter or the 12 Volt DC adapter or separately in the optional Dual Battery Charger Refer to section Symbols and Indica...

Страница 21: ...to the case taking care that the connectors are properly situated in the case top opening You may find it easier to insert the connectors first then pull the corners over the bottom of the Spectrum Ma...

Страница 22: ...and menus are replaced with To enable frequency blanking press the Shift key then the System 8 key Press the System Options submenu key then the Reset submenu key Press the Frequency Blanking submenu...

Страница 23: ...l operation of the instrument along with current measurements This memory is reset whenever the instrument is restarted External USB Flash Drive not included with the instrument This memory may be sel...

Страница 24: ...mmends that you store your Spectrum Master created files on an external USB Flash drive that is then securely retained sanitized or destroyed after use To set the Spectrum Master to save files to an e...

Страница 25: ...art Guide to find directions for power on editing frequency bandwidth amplitude limit line marker file management procedures and firmware update For more detailed information on measurement setups ref...

Страница 26: ...ed as standard accessories refer to the list of accessories in the Technical Data Sheet for your specific instrument as listed in section Introduction on page 1 1 To turn on the MS272xC press the On O...

Страница 27: ...cess the functions that are printed on the panel The Escape key which is used for aborting data entry is the round button located above the submenu keys The rotary knob the four arrow keys and the key...

Страница 28: ...urement display screen the 5 main menu keys The hard keys perform as follows Esc Key Press this key to cancel any setting that is currently being made Enter Key Press this key to finalize data input P...

Страница 29: ...djacent to the measurement display screen and along its lower edge These keys buttons have no printed labels They are positioned to accompany virtual key labels that are displayed in the measurement d...

Страница 30: ...9 key Use the directional arrow keys or the rotary knob to highlight the selection and press the Enter key to select The list of modes that appears in this menu will vary depending upon the options th...

Страница 31: ...ion Menus are active in various operation Modes If any one of these 9 menus is available in a specific instrument Mode of operation then it can be called from the number keypad It may also be availabl...

Страница 32: ...me of the key information areas of the MS272xC display For more detailed key descriptions of the Spectrum Analyzer mode refer to the Spectrum Analyzer Measurement Guide Anritsu part number 10580 00244...

Страница 33: ...ouplers can be added to list boxes by creating them and importing them through the use of Master Software Tools 2 9 Text Entry When entering text as when saving a measurement the submenu key for Text...

Страница 34: ...Text Entry 2 10 PN 10580 00277 Rev E Spectrum Master UG Figure 2 7 Text Entry Menu Lower Case Figure 2 8 Text Entry Menu Upper Case Lowercase Text Entry Uppercase Text Entry...

Страница 35: ...Text Entry Spectrum Master UG PN 10580 00277 Rev E 2 11 Figure 2 9 Text Entry Menu Selecting Characters Rotary Knob has scrolled to letter c...

Страница 36: ...contact fingers of the female connector 2 Push connectors straight together Do not twist or screw them together 3 To tighten turn the connector nut not the connector body Major damage can occur to the...

Страница 37: ...is connector are two LEDs The amber LED shows the presence of a 10 Mbit s LAN connection when on and a 100 Mbit s LAN connection when off The green LED flashes to show that LAN traffic is present For...

Страница 38: ...telephones Ref Out The External Reference Out port is a BNC female connector that provides 10 MHz at approximately 7 dBm to 0 dBm To prevent damage to your instrument do not use pliers or a wrench to...

Страница 39: ...commended torque is 8 lbf in 0 9 N m or 90 N cm 2 12 Symbols and Indicators The following symbols and indicators convey the instrument status or condition on the display Cal Status On The Spectrum Mas...

Страница 40: ...tery automatically receives a charge and the battery symbol with the lightning bolt is displayed Figure 2 12 When the battery is not installed the red plug body is displayed as shown in Figure 2 13 an...

Страница 41: ...bmenu title is shown at the top of the active function block submenu keys labels Refer to Figure 2 2 on page 2 3 Table 2 1 Mode Dependent Main Menu Keys Located Below Measurement Display Mode Key 1 Ke...

Страница 42: ...Firmware Overview 2 18 PN 10580 00277 Rev E Spectrum Master UG...

Страница 43: ...descriptions in the measurement guides for the specific instrument mode and analyzer technology such as Spectrum Analyzer WiMAX or 3GPP Refer to Appendix A Measurement Guides for a list of these measu...

Страница 44: ...he new value Some submenu keys have toggled parameter values On Off Low High On these submenu keys the current value is underlined Press the submenu key to toggle the value Use the arrow keys numeric...

Страница 45: ...pressing the MHz submenu key The current setting is shown at the top of the instrument settings summary column on the left side of the measurement display refer to Figure 2 6 Spectrum Analyzer Display...

Страница 46: ...Set the Measurement Frequency 3 4 PN 10580 00277 Rev E Spectrum Master UG 4 Press the Span RBW submenu key to change the ratio of span width to resolution bandwidth...

Страница 47: ...e Enter key to set The y axis scale is automatically renumbered Note To change the current measurement units press the Units submenu key and select the required units from the submenu keys that are pr...

Страница 48: ...and then press the appropriate submenu key dB External Gain or dB External Loss The new RL Offset value will be displayed on the instrument and reference level is adjusted 3 5 Set the Span Spectrum A...

Страница 49: ...Back submenu key to return to the Limit menu 6 If necessary press the Set Default Limit submenu key to redraw the limit line in view Limit Line Envelope Spectrum Analyzer and Interference Analysis Mo...

Страница 50: ...nd Interference Analysis Modes Figure 3 2 shows an example of a complex limit line After the right half of the limit line was completed the left half of the limit line was built by pressing the Limit...

Страница 51: ...On is underlined The selected marker is displayed in red ready to be moved 3 Use the rotary knob to place the marker on the desired frequency 4 Repeat Step 1 and Step 2 to activate and move multiple...

Страница 52: ...hift then File 7 2 Press the Save Measurement submenu key 3 Press the Change Save Location submenu key and set the current location to be the USB flash drive or internal memory and then press Set Loca...

Страница 53: ...ckly save measurements with a specific file name The Spectrum Master saves the measurement with the latest file name that was used to save a measurement and with a number that is automatically increme...

Страница 54: ...type you want to view Recall a Measurement From the File menu press the Recall Measurement submenu key select the measurement with the rotary knob or the Up Down arrow keys and press Enter Recall a S...

Страница 55: ...1 Insert a USB drive into either USB Type A port of the Spectrum Master 2 From the File main menu press the Copy submenu key The Copy submenu and Copy dialog box are displayed 3 Select the file s to c...

Страница 56: ...rs with the folder Figure 4 3 To expand the symbol highlight the folder and press the Right arrow key 5 Press the Scroll key and highlight the USB drive in the lower window using the Up Down arrow key...

Страница 57: ...ow keys Press the Select or De Select key The file will be highlighted in blue when selected Press the Delete key and Enter to delete the selected file Delete Dialog Box Press the Delete submenu key t...

Страница 58: ...Recall Sort By Name Date Type Sort Order Asc Desc File Type ALL Select or De Select Delete Refresh Directories Delete Sort By Name Date Type Sort Order Asc Desc Scroll Scr Dst File Type ALL Refresh Di...

Страница 59: ...memory or to a USB flash drive The saved setup measurement or JPEG file can be named by using the text entry keys By default measurements are saved in a directory named user to internal memory The sa...

Страница 60: ...tal letters Press the Enter key or the rotary knob to finalize a text entry Back Space Use this key to delete a file name highlighted in blue or delete individual characters Change Save Location Press...

Страница 61: ...ess this submenu key to sort the folders by Name Type or Date Sort Order Displays the folder names in ascending or descending order Create Folder This key will create a new folder in the highlighted l...

Страница 62: ...his submenu key to On will save the measurement to internal memory after the current sweep is complete If Save Then Stop is toggled Off a measurement will be saved after every sweep Save Then Stop Set...

Страница 63: ...t By key File Type Press this submenu key to select what type of file is viewed The options are the ALL Measurement or Setup The file type can be changed with the Up Down keys or the rotary knob Press...

Страница 64: ...Jpeg The file type can be changed with the Up Down keys or the rotary knob Press Enter to make the selection Refresh Directories Press this key to update the display Scroll Press this submenu key to...

Страница 65: ...his submenu key to select what type of file view for deleting The options are the ALL Measurement Setup Limit Lines or Jpeg The file type can be changed with the Up Down keys or the rotary knob Press...

Страница 66: ...4 14 PN 10580 00277 Rev E Spectrum Master UG...

Страница 67: ...77 Rev E 5 1 Chapter 5 System Operation 5 1 Introduction This chapter reviews the Spectrum Master system operations The other menus Sweep Measure Trace and Limit are described in the Measurement Guide...

Страница 68: ...under special circumstances refer to menu descriptions on the following pages Figure 5 1 System Menu Map GPS System Back System Options Application Options GPS GPS On Off GPS Voltage 3 3 V 5 V Status...

Страница 69: ...e test results Press Esc or Enter to return to normal operation Application Self Test Press this submenu key to run a series of tests that are related to the performance of the instrument hardware and...

Страница 70: ...f a mode does not have language translations available then English is the default language Press Enter to accept the change or press the Esc key to return to normal operation without changes In addit...

Страница 71: ...es or to Not Shared Select All Modes to have the current center fre quency setting and power offset setting carried over when changing measure ment modes This function is not applicable to measurement...

Страница 72: ...Default Colors Sets the display colors to their factory default condition Used for normal viewing Black White Sets the display colors to black and white Used for printing and viewing in broad dayligh...

Страница 73: ...hout resetting press Esc rather than pressing Enter Note This same reset sequence can be initiated when turning the Spectrum Master On by pressing and holding the System 8 On keys until the Anritsu sp...

Страница 74: ...attery and if the self test fails then contact your Anritsu Service Center To initiate a self test when the system is already powered up 1 Press the Shift key and then the System 8 key 2 Press the Sel...

Страница 75: ...r the firmware is loaded onto the USB memory device follow the instructions below to update the firmware on your Spectrum Master 1 Insert the USB Memory Stick into the USB port 2 Press the follow key...

Страница 76: ...store User data will be saved to the selected external media device The instrument will also attempt to restore the files to the instrument after the update 6 Press Enter to begin the firmware update...

Страница 77: ...o abort Figure 5 11 8 Select Enter and the firmware update process begins The Firmware Update dialog displays the following message Updating firmware Please Wait 9 When complete the instrument will re...

Страница 78: ...Update Firmware 5 12 PN 10580 00277 Rev E Spectrum Master UG...

Страница 79: ...a must be placed outside without any obstructions In addition to Option 31 the Spectrum Master requires a GPS antenna Anritsu part number 2000 1528 R Activating the GPS Feature 1 Attach the GPS antenn...

Страница 80: ...arts per billion The OCXO internal standard accuracy is 0 3 PPM The correction factor applied to the internal OCXO allows the instrument to maintain GPS frequency accuracy for three days at better tha...

Страница 81: ...3 MST Feature Overview Capturing or Retrieving Traces MST includes a feature to capture the current screen and associated data from the test instrument to the Master Software Tools Graphic Display Edi...

Страница 82: ...on the CD ROM that is included with the instrument Insert the CD ROM into a PC to run the installer Follow the onscreen instruction 7 5 Updating Instrument Firmware 1 Connect the Spectrum Master to a...

Страница 83: ...can immediately click Install to Unit to update your Spectrum Master with the new firmware File Status Available In Figure 7 4 the status of the highlighted file is Available and the Install to Unit b...

Страница 84: ...7 4 PN 10580 00277 Rev E Spectrum Master UG Note Screen captured images are provided as examples The images shown on your instrument may differ from the examples in this user guide Figure 7 3 Product...

Страница 85: ...l to Unit button Your Spectrum Master is updated with the new firmware File Status Available 1 Check that the file status is Available 2 Click Retrieve File to download the file from the Web site to y...

Страница 86: ...d from the Web site to your PC 3 After the status changes to Ready click the now active Install to Unit button Your Spectrum Master is updated with the new firmware Update Problems If you do not find...

Страница 87: ...nnel Scanner 0027 Zero Span IF Output 0089 AM FM PM Analyzer 0509 Spectrum Analyzer Measurement Guide 10580 00244 High Accuracy Power Meter 0019 Power Meter Measurement Guide 10580 00240 GSM GPRS EDGE...

Страница 88: ...0066 IEEE 802 16 Mobile WiMAX Demodulated Signal Analyzer 0067 IEEE 802 16 Mobile WiMAX Over the Air Signal Analyzer 0037 WiMAX Signal Analyzer Measurement Guide 10580 00236 Performance Specification...

Страница 89: ...m Master UG PN 10580 00277 Rev E A 3 Table A 3 Additional Instrument Supplements Supplement Type Part Number Handheld Instruments Documentation Disc 10920 00060 Computer Software Application Master So...

Страница 90: ...Documents Firmware Supplemental Information A 4 PN 10580 00277 Rev E Spectrum Master UG...

Страница 91: ...ment traces and return the unit to a fully Factory Default condition If the error persists then contact your Anritsu Service Center DDC FAILED The Digital Down Converter failed to return a value Insur...

Страница 92: ...s it may be necessary to add an external band pass filter to reduce unwanted interference See the accessories section for a list available band pass filters from Anritsu Out of band frequencies can of...

Страница 93: ...nna correction files Minimum permitted Sweep time is 50 s An attempt was made to set the minimum Sweep time to less than 50 s Invalid Attenuation for Preamp The only valid attenuation settings while t...

Страница 94: ...reference frequency is at least 1vp p Fatal error EEPROM failed Hardware communications between modules has failed Insure that the battery level is adequate for operation or that temperature is withi...

Страница 95: ...rent Marker is not ON Attempted to use a marker mode or feature for a marker that is not enabled Turn on the appropriate marker to use this function or switch to a marker that is already enabled Marke...

Страница 96: ...faults ESC ON or MASTER RESET System ON Caution Use of MASTER RESET System ON will erase all user saved setups and measurement traces and return the unit to a fully Factory Default condition If the er...

Страница 97: ...urn itself off before internal temperatures can cause any damage If the error persists after removing any obstructions and allowing the unit to cool then reset to the factory defaults with either Fact...

Страница 98: ...Operation Error Messages B 8 PN 10580 00277 Rev E Spectrum Master UG...

Страница 99: ...amic Host Configuration Protocol DHCP is an Internet protocol that automates the process of setting IP addresses for devices that use TCP IP and is the most common method of configuring a device for n...

Страница 100: ...nt on press the Shift key then the System 8 key then the System Options submenu key and the Ethernet Config submenu key The IP address will be displayed as shown in Figure C 1 The image on the display...

Страница 101: ...ster UG PN 10580 00277 Rev E C 3 Ethernet Config Press this submenu key to display the Ethernet submenu and to open the Ethernet Editor dialog box in order to set the IP address of the instrument Figu...

Страница 102: ...ccept the changes or press the Esc key to return to normal operation without changing anything Field IP G Way Sub Press this submenu key to select the desired Internet Protocol Property to be edited F...

Страница 103: ...must be taken to not conflict with other equipment on the network When using a static IP address on an established network always request the Static IP address from the network administrator Randomly...

Страница 104: ...inations about the network to which the PC is connected Typing ipconfig at a command prompt produces a display of information about the in use parameters of the PC and its network connection Following...

Страница 105: ...ection is found then a copy of the signal that was sent is returned If a connection is not found then the response is request timed out which means that no reply was received from that IP address Y pi...

Страница 106: ...C 8 PN 10580 00277 Rev E Spectrum Master UG...

Страница 107: ...5 ESD 1 6 center frequency settings 3 3 center frequency sharing 5 5 change directory 4 8 cleaning RF connectors 1 5 connectors test panel illustration 2 13 contacting Anritsu 1 1 copy menu 4 12 creat...

Страница 108: ...formation C 1 LAN connection 2 13 C 1 remote access password 5 5 latitude GPS 6 1 LCD Spectrum Master display 1 4 limit lines setup 3 7 links contacting Anritsu 1 1 MS2722C product page 1 1 longitude...

Страница 109: ...5 5 secure data 1 10 self test at power on 5 8 application self test submenu key 5 3 self test submenu key 5 3 service centers 1 7 set remote access password key 5 5 share center freq and power offse...

Страница 110: ...W to W Index 4 PN 10580 00277 Rev E Spectrum Master UG web links MS2722C product page 1 1 website contacting Anritsu 1 1 windows operating system support MST 7 1...

Страница 111: ......

Страница 112: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA Anritsu prints on recycled paper with vegetable soybean oil ink...

Отзывы: