2-34 Measure Menu
Spectrum Analyzer
2-80
PN: 10580-00349 Rev. M
Spectrum Analyzer MG
For more information on creating and editing mask segments, refer to
“Spurious Emissions (Out-of-Band)” on page 2-31
Spurious Segment:
Press this submenu key to select the number of a
segment to be edited or swept. The key is active only when the segment
number is highlighted in red. Use the directional arrow keys, rotary knob, or
numeric keypad to enter the desired number.
Save Current Settings to Selected Segment:
Press this submenu key to
save the data in the display and all of the supported data for the selected
spurious segment in the Spurious Emission table. See
Figure 2-20
on page 2-35
Add Current Settings As New Segment:
Creates a new segment with the
current parameter set. The new segment will be appended to the end of the
list in the Spurious Emission table.
Delete Current Segment:
Deletes the current segment from the Spurious
Emission table.
Segment Start Amplitude:
Press this submenu key to set a value for the
segment’s start limit amplitude. When the value is highlighted in red, use the
directional arrow keys, rotary knob, or numeric keypad to enter the amplitude
value.
Segment Stop Amplitude:
Press this submenu key to set a value for the
segment’s stop limit amplitude. When the value is highlighted in red, use the
directional arrow keys, rotary knob, or numeric keypad to enter the amplitude
value.
Save Mask:
Saves the mask data from the display and Spurious Emission
table and all supporting mask data into the mask data file.
Back:
Returns to the previous menu.
Figure 2-66.
Spurious Segments Submenu
Spurious Segments
Back
Save Mask
Spurious Segment
1
Segment Stop
Amplitude
10.0 dBm
Segment Start
Amplitude
10.0 dBm
Delete
Current Segment
Add Current
Settings As
New Segment
Save Current
Settings to
Selected Segment
Содержание BTS Master
Страница 103: ...Spectrum Analyzer 2 35 Trace Menu Spectrum Analyzer MG PN 10580 00349 Rev M 2 91 Figure 2 78 Trace Info...
Страница 246: ...6 6 Coverage Mapping Menu Coverage Mapping Option 431 6 24 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 278: ...7 21 Marker Menu AM FM PM Analyzer Option 509 7 32 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 282: ...8 2 Bias Tee Menu Bias Tee Option 10 8 4 PN 10580 00349 Rev M Spectrum Analyzer MG...
Страница 295: ......