ArcSource Outdoor 24 MC Integral SmartWhite
7
3.3 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulation.
This device falls under class one and must be grounded!
The ArcSource Outdoor 24 MC Integral is equiped with with a 5-cored power/data cable. The 3 cores serve for
the power supply and next 2 shielded cores are intended for DMX connection as shown the table.
Core
Connection
Core
Connection
Black
Live
Red
Data +
Blue
Neutral
White
Data -
Yellow/Green
Shielding
0
The power/data cable is connected to a junction box as shown on the picture below.
Connect the junction box acording to the tables below
Power connection
L
N
EU
Braun
Blue
Green/yellow
US
Black
White
Green
DMX connection
+
0
-
Data +
Data ground(shielding)
Data -