background image

version 1.2

Содержание arcpower smartwhite 72

Страница 1: ...version 1 2...

Страница 2: ...ynet protocol 9 6 ArcPower SmartWhite 72 Control menu map 11 7 ArcPower SmartWhite 72 DMX protocol 12 8 Control board 13 8 1 Addressing the ArcPower SmartWhite 72 13 8 2 Program running 13 8 3 Manual...

Страница 3: ...pairs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has t...

Страница 4: ...tor 2 Control board 3 DMX Output 4 DMX Input 5 LED Zone 1 output 6 LED Zone 2 output 7 RS 232 Output 8 Fuse Holder 9 Power Cord Pin 1 Not connected Pin 5 Not connected Pin 2 12V Pin 6 Data Pin 3 Not c...

Страница 5: ...orientation and fixed by the two screws There are two mounting holes of diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cab...

Страница 6: ...non DMX 512 device e g Ethernet network Hub can damage the ArcPower SmartWhite 72 Maximum total cable length between one LED zone output of the ArcPower SmartWhite 72 and all its connected LED module...

Страница 7: ...one of the ArcPower SmartWhite 72 Model total LEDs Warm White LEDs Cool White LEDs Max number of connected modules ArcLine SmartWhite Optic 12 12 6 6 3 ArcLine SmartWhite Optic 24 24 12 12 1 ArcLine S...

Страница 8: ...t with the input of the next slave until all slaves are connected Up to 32 fixtures can be connected in master slave chain 4 Insert the termination plug with 120 Ohm into DMX input of the master fixtu...

Страница 9: ...t fixture in a data link with the DMX input of the second fixture Always connect output with the input of the next fixture until all fixtures are connected Up to 32 fixtures can be con nected in data...

Страница 10: ...e Channel Offset if more than 4 channels Channel Offset 0 255 default FF channel offset in blocks of 4 FF CH 1 4 00 CH 5 8 01 CH 9 12 etc up to 3E CH 253 256 Fade Rate 0 255 fade rate with 1 second re...

Страница 11: ...6 Aut OFF On EdI E P 1 E P 2 E P 3 S 01 S 30 End VAr 0 255 FA t 0 255 S tI 0 255 COP MAn VAr 0 255 CoL 0 255 VA2 0 255 Co2 Str 0 255 diM 0 255 tSt St A MSt E P 1 P06 SLA SPE VEr Zon Z 00 Z 08 d MP Mo...

Страница 12: ...l 2 0 127 0 127 128 255 128 255 Ratio control 2 100 Warm white LED saturation Cool white LED saturation 0 100 100 Cool white LED saturation Warm white LED saturation 100 0 step proportional step propo...

Страница 13: ...define the starting DMX address from which the ArcPower SmartWhite 72 will respond to the DMX controller Setting the DMX start channel for DMX operating 1 Connect ArcPower SmartWhite 72 to the mains 2...

Страница 14: ...ble in order to convert DMX value to the time value DMX Time sec DMX Time min DMX Time min DMX Time min DMX Time min 1 0 1 50 4 2 105 18 4 160 42 7 215 77 2 0 4 55 5 110 20 2 165 45 4 220 80 7 5 2 5 6...

Страница 15: ...editable program EP 1 all slaves will execute their own editable programs EP 1 according the master but both fade time FA t and standing time S tI for each step will be taken from the master s step s...

Страница 16: ...e archives Program file has name DSU_name of corresponding fixture_SoftwareID SoftwareID describes the versions of fixture software included in DMX Software Uploader Higher number means later software...

Страница 17: ...in menu of the ArPower 72 press ENTER use UP and DOWN buttons to select Zon The option enables to select desired number of the zone from 0 to 8 Press ENTER use UP and DOWN buttons to select zone numbe...

Страница 18: ...Examples zone 4 warm zone 0 blackout Type 2 Colour mixing The syntax of the command is zone Z w c Z means number of zone 0 9 w means DMX value of the warm white colour 0 255 c means DMX value of the c...

Страница 19: ...n one LED zone output and all its connected LED modules 80 metres at max load DMX channels Mode 1 4 channels Mode 2 1 channel Mode 3 3 channels Mode 4 6 channels Mode 5 3 channels Mode 6 6 channels Co...

Страница 20: ...eplacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower SmartWhite 72 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the f...

Отзывы: